Showing posts with label WATLOW. Show all posts
Showing posts with label WATLOW. Show all posts

Thursday, April 29, 2021

Watlow Solid State Relays

Sords Electric Sells Watlow Solid State Relays

Buy Watlow SSRs HERE!

The power controller is a discrete output device that regulates your system with guidance from the temperature controller. There are three common power controllers: electromechanical relays, solid-state relays and silicon-controlled rectifiers (SCRs).

Watlow solid state relays (SSR) offer many of the advantages of solid state power controllers, but at a lower cost. Watlow's extensive knowledge in power controller design led to the development of a special fast cycle input card that enables a solid state relay to operate from a standard 4-20mA instrumentation command signal. Test results show that zero-cross solid state relays in combination with the fast cycle card promote better temperature control and longer heater life than slow cycle relays. Through a time proportional cycle rate of 1⁄10 of a second, heater life will be extended.

Both low and high voltage solid state relays are available from 24 to 660VAC. All ac output models include back-to-back silicon controlled rectifiers (SCRs) for a more rugged design than the traditional triac-based solid state relay. The internal design allows it to tolerate high currents and harsh electrical environments of heavy industry. Watlow also offers a switched VDC model for dc heating applications.

Watlow provides all of the components necessary for trouble-free operation. This includes two standard convenience items: a thermal foil to ensure proper thermal transfer from the relay to the heat sink and belleville washers to ensure that the relay is mounted with sufficient pressure to enable good heat transfer. Matched semiconductor fuses and heat sinks are available to complete the power switching package.

Watlow SSR Solid State Relay










AC input, 75 Amps
AC input, 50 Amps
AC input, 25 Amps
DC input, 75 Amps
DC input, 50 Amps
DC input, 25 Amps
DC input, 50 Amps
DC input, 25 Amps
DC input, 10 Amps

Relays may need to be deRated based on ambient temperature or how and where they are mounted. The rule of thumb is to only switch 80% of the amp rating.

For three phase use, please use 3 relays, one per phase.

UL recognized File #151484 and #E73741 CSA certified up to 600VAC, File #LR700195 VDE 60950 License # 40021401, File #1995500 up to 480VAC, CE

Buy Watlow SSRs HERE!

Sords Electric
Cleveland, Ohio
www.sordselectric.com

Sunday, November 29, 2020

Littelfuse SIR Solid State Relays

 SIR Littelefuse Solid State Relays from Sords Electric


The Littelfuse SIR Series is designed for industrial applications requiring rugged reliable operation. Provides an optically isolated, high capacity, solid-state output, with power switching capability up to 20A steady state, 200A inrush. Zero voltage switching SIR2 extends the life of an incandescent lamp up to 10 times. Random switching SIR1 is ideal for inductive loads. When fully insulated female terminals are used on the connection wires, the system meets the requirements for touch-proof connections.

Contact Sords Electric HERE!

Littelfuse SIR 20 Amp Solid State Relays








Operation:

The solid-state output is located between terminals 1 and 3, and is normally open or normally closed without control voltage applied to terminals 4 and 5. When control voltage is applied to terminals 4 and 5, the solid-state output opens or closes respectively. Reset: Removing control voltage resets the output. The unit is also reset if output voltage is removed.


FEATURES    >>>    BENEFITS 

Compact design measures 2 in. (50.8mm) square >>  Perfect for OEM applications where space is limited 

Totally solid state and encapsulated >>  No moving parts to arc and wear out over time and encapsulated to protect against shock, vibration and humidity 

Up to 20A, 200A inrush output rating >>  Provides direct control of heavy inductive, incandescent or resistive loads 

Switching output is optically isolated from the control input  >>  Provides the ability to interface between 2 different electrical circuits 

SIR1 models provide random switching >>  Designed for use with resistive and incandescent loads, extending lamp life up to 10 times 

SIR2 models provide zero voltage switching >> Perfect for resistive and incandescent loads

Metalized mounting surface >> Facilitates heat transfer in high current applications


Littelfuse Model Numbers

MODEL   SWITCHING   CONTROL VOLTAGE  RATING  OUTPUT FORM   OUTPUT VOLTAGE 

SIR1A1A4  Random  9 to 30VAC or DC 3A Normally open 120VAC 

SIR1A20A4  Random 9 to 30VAC or DC 20A Normally open 120VAC 

SIR1B6B4  Random 90 to 150VAC or DC 6A Normally closed 120VAC 

SIR1C20B6  Random 190 to 290VAC or DC 20A Normally closed 230VAC 

SIR2A20A4  Zero Cross 9 to 30VAC or DC 20A Normally open 120VAC 

SIR2B20A4  Zero Cross 90 to 150VAC or DC 20A Normally open 120VAC 

SIR2B20B4  Zero Cross 90 to 150VAC or DC 20A Normally closed 120VAC

Contact Sords Electric HERE!

Sords Electric
216-765-4230
www.sordselectric.com

Littelfuse SIR1...Littelfuse SIR2...Littelfuse SIR1...Littelfuse SIR2...Littelfuse SIR...1

Friday, April 17, 2020

Sords Electric NEW Website

Sords Electric announces a brand new Website Platform.

We accept VISA, AMEX, M/C, Discover and PayPal

For a quote please contact us HERE!

Brands represented:

AmerimationConvectronicsMDITECO Westinghouse
ATCDanfossMeltricToshiba
AutonicsDiversified ElectronicsPepperl+FuchsTRC
BarksdaleFenwalQ'MarkUnited Electric Controls
BoschJessupRobertshaw Schneider ElectricWatlow
BriskHeatKidde FenwalSSACWeintek
Carlo GavazziLittelfuseStiebel-Eltron 
ChromaloxLovato ElectricTapeswitch 

Parts and Components
Electric Heaters
Strip, Cartridge, Band, Air, Unit, Wall, Radiant, Heating Cable, Drum, Water
Timers - Counters - Time Delay Relays
Current Monitors, Voltage Monitors, Phase Monitors, Voltage Alerts
Power Switching Devices
Contactors, Solid State Relays, SCRs, 
Switches
Proximity, Level, PhotoElectric, Inductive, Capacitance, Vibration, Pressure
Temperature Controls
THERMOSWITCH, Process DIN Controls, Detect-A-Fire Switches
Motors and Drives 
Uninteruptible Power Supplies 
Pin and Sleeve Connectors
HMIs
Ground Fault Circuit Interrupters - GFCIs
For a quote please contact us HERE!
Sords Electric - 216-765-4230

Sunday, September 29, 2019

Watlow Mineral Insulated Strip Heaters

MI - Mineral Insulated Strip Heaters from Watlow

Get a Quote HERE! from Sords Electric















The MI strip heater is a thin, responsive heater that uses the most advanced heater construction techniques. A nickel-chromium element wire is embedded in Watlow’s exclusive mineral insulation material, which has a much higher thermal conductivity than the mica and hard ceramic insulators used in conventional heaters. This thin layer of insulation brings the element wire closer to the heater sheath. The result is heat flows easily from the element wire to the sheath allowing the wire to run cooler than conventional heaters and increasing heater life.

Higher watt densities than any other strip heater for faster heat-up

Exclusive mineral insulation combines dielectric strength and superior thermal conductivity

304 stainless steel sheath maintains the high compaction of mineral insulation

UL® component recognition for most 240VAC or less designs

480VAC maximum voltage

Rapid ship Part Numbers are:

MS1J8AS3 - 240 VOLT 500 WATT
MS1J12AV2 - 120 VOLT 350 WATT
MS1J12AV3 - 240 VOLT 350 WATT
MS1J12AS2 - 240 VOLT 800 WATT
MS1J18AS1 - 120 VOLT 1000 WATT
MS1J18AS2 - 240 VOLT 1000 WATT

Get a Quote HERE

Sords Electric
216-765-4230
www.sordselectric.com

WATLOW MINERAL INSUlATED STRIP HEATERS ... WATLOW MINERAL INSUlATED STRIP HEATERS

Sunday, August 18, 2019

Watlow Mineral Insulated Band Heaters

Sords Electric Sells Barrel and Band Heaters from Watlow

Mineral Insulated (MI) Band/Barrel Heaters

The MI band heater from Watlow® is a high-performance heater. The band heater's performance and name are derived from Watlow's exclusive mineral insulation—a material with much higher thermal conductivity than mica and hard ceramic insulators used in conventional heaters. A thin layer of the “high” thermally conductive MI material is used to electrically insulate the element wire from the inside diameter of the heater sheath. A thicker, “low” thermally conductive layer backs up the element wire directing the heat inward toward the part being heated. 

High thermal conductivity of MI and low mass construction provides rapid response to temperature control and avoids thermal lag.

Operating temperatures up to 1400°F (760°C) allows safe melting of resins such as PEEK™, Teflon®, Ultem® and Zytel®

Higher watt densities contribute to faster heat-up and throughput for increased productivity

Stainless steel cover and side fold design resists contamination from overflow of plastic or other free-flowing materials

Attached clamp bars eliminates cumbersome clamping straps, making installation easier

Applications and Technical Data 
General Limitations 
Maximum width of 1 in. (25 mm) diameter heater is 11/2 in. wide (38 mm) 
Maximum heater width: 2x heater diameter 
Minimum I.D. for Type B, C, E and H leads: 1 in. (25 mm) 
Minimum I.D. for Type B—90° leads: 11/8 in. (29 mm) 
Maximum lead amperes: 12.5A per pair 
SLE maximum: 17.0A 
Maximum amperes (post terminals): 30A per pair 
Minimum diameter and width for SLE: 4 in. x 11/2 in. (102 x 38 mm) width 
90° leads not available over 250VAC 
Minimum I.D. for post terminals: 11/4 in. (32 mm) 
Gaps 
≤ 3 in. = 1/8 in. nominal 
3 in. ≤ 6 in. = 1/4 in. nominal ±1/8 in. 
6 in. ≤14 in. = 3/8 in. nominal ±1/8 in. 
>14 in. = 1/2 in. nominal ±1/4 in. 

Use our Contact Form HERE to get a quote on Watlow Band /BarrelHeaters














MB1A1AN1
MB1A1AN2
MB1A1AN3
MB1A1AN4
MB1A1JN1
MB1A1JN2
MB1A1JN3
MB1A1JN4
MB1A1JN5
MB2A1JN1
MB1E1AN2
MB1E1AN3
MB1E1JN1
MB1E1JN2
MB1E1JN3
MB1J1AN1
MB1J1AN2
MB1J1AN3
MB1J1AN4
MB1J1AN5
MB1J1JN1
MB1J1JN2
MB1J1JN3
MB1J1JN4
MB1J1JP4
MB1J1JP6
MB1J2AN1
MB1J2AN2
MB1J2AN3
MB1J3AN1
MB1J3AN2
MB1J3AN3
MB1N1GX3A
MB1N1JN1
MB1N1JN2
MB1N1JN3
MB1N2AN1
MB2A1AN1
MB2A1AN2
MB2A1AN3
MB2A1AX6B
MB2A1JN1
MB2A1JN2
MB2A2AN1
MB2A2AN2
MB2A2AX2A
MB2E2AX7
MB2E2JN1
MB2J1AN1
MB2J1JN1
MB3A1AP1
MB3A1JP1
ME3A1JP10
MB3J2AP2
ME3L1JP5
MB4A1AP1
MB4A1JP2
ME4A1JP11
ME4A1JP12
MB4J2JP1
ME5A1JP8
ME5E1JP9
ME5E3AP5
ME5E4JP2
ME5E4JP3
ME5J1JP1
ME6A1JP2
ME6J1JP5
ME6N1JP6
ME6N1JP7
ME6N4AP2
ME6N5AP3
ME6N6AP5
ME7A1JP4
ME7J1JP4
ME7L3AP1
ME8A1JP4
ME9A1JP1
ME9J3AP2
ME11E3AP2
ME11E5AP1













Use our Contact Form HERE to get a quote on Watlow Band /Barrel Heaters

Sords Electric
216-765-4230
www.sordselectric.com

Band Heaters and Barrel Heaters from Watlow 

Friday, August 9, 2019

Watlow Nozzle Heaters

Sords Electric Sells Watlow Mineral Insulated Nozzle Heaters

Use our Contact Form HERE to get a quote on Watlow Nozzle Heaters

Mineral Insulated Nozzle Heaters

The MI nozzle heater from Watlow is a high-performance heater. The nozzle heater's performance and name are derived from Watlow's exclusive mineral insulation—a material with a much higher thermal conductivity than mica and hard ceramic insulators used in conventional heaters.

A thin layer of the “high” thermal conductive MI material is used to electrically insulate the element wire from the inside diameter of the heater sheath. A thicker, “low” thermal conductivity layer backs up the element wire, directing the heat inward toward the heated part. The result is more efficient heat transfer—a performance solution lowering element wire temperatures and increasing heater life.



Performance Capabilities
• Heater operating temperatures up to 1400°F (760°C)
• Watt densities up to 230 W/in2 (35.6 W/cm2) are
   available on small diameter nozzle


• Maximum voltage up to 240V
Operating temperatures to 1400°F (760°C) safely melts resins such as PEEK®, Teflon®, Ultem® and Zytel®
Higher watt densities contribute to faster heat-up and throughput for increased productivity
High thermal conductivity of MI and low mass construction provides an almost instant response to temperature control
Stainless steel cover and side fold design resists contamination by overflow of plastic or other free-flowing materials
Permanently attached clamp bars eliminate cumbersome clamping straps for easier installation


Typical Applications
• Extruders
• Blown film dies
• Injection molding machines

• Other cylinder heating applications










Watlow nozzle Heater Part Numbers.
MB1A1AN1
MB1A1AN2
MB1A1AN3
MB1A1AN4
MB1A1JN1
MB1A1JN2
MB1A1JN3
MB1A1JN4
MB1A1JN5
MB1E1AN1
MB1E1AN2
MB1E1AN3
MB1E1JN1
MB1E1JN2
MB1E1JN3
MB1J1AN1
MB1J1AN2
MB1J1AN3
MB1J1AN4
MB1J1AN5
MB1J1JN1
MB1J1JN2
MB1J1JN3
MB1J1JN4
MB1J1JP4
MB1J1JP6
MB1J2AN1
MB1J2AN2
MB1J2AN3
MB1J3AN1
MB1J3AN2
MB1J3AN3
MB1N1GX3A
MB1N1JN1
MB1N1JN2
MB1N1JN3
MB1N2AN1
MB2A1AN1
MB2A1AN2
MB2A1AN3
MB2A1AX6B
MB2A1JN1
MB2A1JN2
MB2A2AN1
MB2A2AN2
MB2A2AX2A
MB2E2AX7
MB2E2JN1
MB2J1AN1
MB2J1JN1

Use our Contact Form HERE to get a quote on Watlow Nozzle Heaters

Sords Electric
216-765-4230
www.sordselectric.com

Watlow Nozzle Heaters for Industrial Uses

Saturday, March 30, 2019

Selecting Solid State Relays

Sords Electric Sells SSRs or Solid State Relays
Selecting the right relay is important for long life and application efficiency.





BUY SSRs HERE!

Here is guide to selecting and installing (SSRs) Solid State Relays.

A solid state relay or SSR is an electronic device that switches loads on or off when an external voltage or signal is applied to its control terminals. The lack of moving parts in an SSR allows it to switch much faster that electromechanical relays while avoiding the creation for electrical arcs. Solid Sate Relays are also silent, so users won't be subjected to the annoying noise associated with electromechanical relays. Furthermore, because SSRs have no moving parts or contacts that can wear out, SSRs last longer and require less maintenance than electromechanical relays.

SSRs are used in a variety of applications where quick, silent switching is advantageous. Some of these industries include: plastics/rubber, Food and beverage, processing, packaging, HVAC, semiconductor, oil/gas, transportation, conveyors, power or energy systems, printing, laboratory,kiln/oven, lighting, medical/pharmaceutical, and motion control.

How will your solid state relays be mounted/installed?


SSRs are available in a few mooting configurations. Printed circuit board (PCB) mont SSRs are limited in load size due to electric creepage and clearance distance and heat dissipation constraints.
Chassis munt SSRs are often installed to a back panel of an electrical panel but may also mount directly to a metal surface within a machine or appliance. Typically, the SSR can be mounted without a heat sink if the load is un 5 amps or under 8 amps if the mounting surface is an unpainted metal plate. To achieve the desired maximum SSR output rating, a sink sink must be properly sized and installed along with the SSR.

Engineers wo tont want to worry about properly sizing and mooting a heat sink can opt for an SSR with an integrated heat sink. These typically snap directly onto the DIN rail and are ready to wire up and use. Many of the more advanced Ssts, such as those enabling proportional control, are available in this design.  Is it also easier to obtain agency approval with SSRs integrated heat sinks, which are typically cUL listed and carry horse power ratings.

How Many Poles Need to be Switched?


When selecting a Solid State Relay, you will need to know how many polkas  (or lines of voyage) are to be switched to the load.  If your application uses a DC load, you'll need a one pole DC switching SSR. For a single-phase AC load you'll need a one pole AC switching SSR.  For a three phase AC load, you'll need to determine if you want to switch all three poles to the load or if you can get by with only switching 2 poles.  This can be achieved with a two-pole or three-pole three phase switching SSR.

What is Your Load Voltage and Current?


You will need to determine the maximum AC or DC voltage and current for your load. These variables are typically found on the specification of your motor, heater or other electrical device. For AC loads, SSRs usually switch on phase at 120 or 240 VAC or for three phase applications: 208, 240, 480 or 600 VAC.  Also factor in any potential power sags or surges in the application location when determining the minimum and maximum load voltage. DC loads are gong to be powered by DC voltage.
For motors, you will need to know the maximum horse power or kilowatt rainy at the respective voltage of your application. Check for these specs on the motor name plate.

What is the control voltage or input signal to turn the SSR on?


Next you'll need to determine another kind of voltage, the pick-up voltage that is required to energize your load as its turn off voltage (at which your load will de-energize). These are the critical control voltages for your SSR, and are usually found on your loads spec sheet. Unlike electromechanical relays or contractors which typically are controlled by a fixed voltage, SSrs have input ranges either VDC or dual VAC/VDC.
If you wish to proportionally control your load, you'll need some additional specs to choose the proper SSR. Proportional control is typically done with a 0-5, 1-5 or 0-10 VDC input or a 4-20mA control signal. Be sure to consult with a SSR manufacturer to determine the optimum out-put switching type for your load application, as it can get a bit sophisticated. Proportional output types include phase angle, distributed full cycle, burst full cycle, soft start and burst full cycle with soft start.

What is the Ambient temperature where the SSR will be installed or located?


The maximum SSR current rating depends upon the ambient temperature where is will be used and installed. Heightened temperatures can reduce the SSRs current rating.  Any SSRs are mounted on a chassis and require a heat sink t ptomaine their performance. you will need to know the ambient temperature, as well as the mounting orientation upfront, to properly ensure the right type of heat sink is specified.  Highly competent SSR manufacturers provide online tools to help match single or multiple SSRs with the appropriate heat sink. With Din rail mountable SSRs the heat sink is already integrated and the ratings are typically listed on the side of the device or data sheet for various ambient temperatures.  Keep in mind that higher ambient temperatures will require you to de-rate the current rating of the Solid State Relay.


BUY SSRs HERE!



Sords Electric
216-765-4230

Thursday, January 31, 2019

Watlow Tubular Heating Elements - WATROD

Watlow WATROD tubular Heating Elements from Sords Electric

CONTACT SORDS ELECTRIC, HERE!

The Watlow WATROD tubular heating elements come in either single or double ended termination styles.  The versatile and economical WATROD heating element fem Watlow lends s itself to virtually the range of immersion and air heating applications.

The single ended WATROD tubular design has both terminals at one end.  The opposite end is sealed. Flexible lead wires are 12 inches (305mm) crimp connected to the terminal pin and have a silicone-impreganted fiberglass over sleeves.

The double ended WATROD, with its round cross-sectional geometry is highly adaptable for bending- especially when bending is done in the field. Watlow's doulbe-ended MULTICOIL tubular elements offer various combinations of resistor coils and thermocouples inside one sheath. They have the ability to sense the heater's internal temperature accurately every time, or offer three phase capability in one element.

Both Single and double ended WATRODs share many construction features delivering long life- the resistance wire is centered in the heater sheath and electrically insulated  with compacted, high grade magnesium oxide, MgO, for superior heating performance.

WATROD heating elements have a variety of mounting and termination options making them highly popular among industrial customers.

Single-Ended WATROD Performance Capabilities

* Watt Densities up to 45 W/inches squared.
* UL and CSA component recognition up to 240VAC
*Alloy 800/840 and stainless steel sheath temperatures up to 1200ºF

Double-Ended WATROD Performance Capabilities

* Watt Densities up to 120W/inches squared.
* UL and CSA component recognition up to 600VAC
*Alloy 800/840 and stainless steel sheath temperatures up to 1600ºF
* Stainless Steel sheath temperatures up to 1200ºF
* Steel sheath temperatures up to 750ºF
* Alloy 800 sheath temperatures up to 1800ºF

Features and Benefits

Precision wound nickel-chromium resistance wire that distributes heat evenly to the sheath for optimum heater performance.
Silicon resin seals to protect against moisture contamination and is rated to 221ºF.
MgO insulation filled sheath to maximize dielectric strength, heat transfer and heater life.
Standard sheath materials include Steel, 304/316 stainless Steel, alloy 800/840 and alloy 600.
The 53 standard bend formations allows forming the heating element to the application and includes spirals, compound bends and multi-axis/multi-plane configurations.
Stainless Steel Studs are fusion welded to the terminal pins for mechanical strength.

Applications include:

Direct Immersion, Hot Runner Mold, Forced Air, Ovens, Radiant, Clamp-On,
Vacuums, Semiconductor, Platens, Deicing antennas, Plastic Wrap, Seal Bars

Element Diameters, Sheath Lengths and Max Volts and Amps:

Dia.   Volts         Amps    Length
.260  250VAC  15 amps  9" to 270"
.315  480VAC  30 amps  9" to 270"
.375  480VAC  30 amps  11" to 360"
.430  600VAC  40 amps  11" to 360"
.475  600VAC  40 amps  11" to 275"


FOR A QUOTE, USE OUR CONTACT US FORMHERE!

Watlow RGS Tubular Series WATROD Elements

MEDIUM WEIGHT, NON-CIRCULATING, HEAT TRANSFER OILS
15 Watts per Sq. Inch, Steel Sheath
Sheath Lengths from 29 inches to 143 inches
Wattages from 500 to 3000 (3kw)

240 VOLT PART NUMBERS
RGSS29R10S, RGSS38G10S, RGSS44G10S, RGSS53G10S, RGSS68G10S 
RGSS83G10S, RGSS98G10S, RGSS120G10S, RGSS142R10S

480 VOLT PART NUMBERS
RGSS38G11S, RGSS44G11S, RGSS53G11S, RGSS68G11S
RGSS83G11S, RGSS98G11S, RGSS120G11S, RGSS142R11S

Watlow RCN Tubular Series WATROD Elements

AIR HEATING
20 Watts per Sq. Inch, ALLOY 840 Sheath, .430 Diameter
Sheath Lengths from 48 inches to 92 inches
Wattages from 1000 to 2083

240 VOLT PART NUMBERS
RCN48N10S, RCN58N10S

480 VOLT PART NUMBERS
RCN48N11S, RCN58N11S, RCN73N11S, RCN91N11S

AIR HEATING
30 Watts per Sq. Inch, ALLOY 840 Sheath, .430 Diameter
Sheath Lengths from 15 inches to 120 inches
Wattages from 400 to 5000 (5kw)

240 VOLT PART NUMBERS
RCN1510S, RCN2010S, RCN2510S, RCN3010S, RCN3510S, RCN4010S
RCNX48N10S, RCN4510S, RCN5010S, RCNX58N10S, RCN5510S, RCN6010S
RCN6510S, RCN7010S, RCN7510S, RCN8010S, RCN9010S, RCN10010S
RCN11010S, RCN12010S

480 VOLT PART NUMBERS
RCNX48N11S, RCNX58N11S, RCNX73N11S, RCNX91N11S

Watlow RBN and RGN Tubular Series WATROD Elements

CAUSTIC SOLUTIONS or AIR HEATING
23 Watts per Sq. Inch, ALLOY 800 Sheath, .315 and .475 Diameter
Sheath Lengths from 29 inches to 157 inches
Wattages from 500 to 5000 (5kw)

120 VOLT PART NUMBERS
RBN291S, RBN401S, RBN511S, RGNA391S

240 VOLT PART NUMBERS
RGNA3910S, RGNA5410S, RGNA6910S, RGNA8410S,
RGNA9910S, RGNA13210S, RGNA15710S

Watlow RBS Tubular Series WATROD Elements

LIGHT WEIGHT, HEAT TRANSFER OILS
23 Watts per Sq. Inch, Steel Sheath, .315 Diameter
Sheath Lengths from 16 inches to 77 inches
Wattages from 250 to 1500 (1.5 kw)

120 VOLT PART NUMBERS
RBS161S, RBS181SRBS211SRBS23G1SRBS28R1S 
RBS291SRBS421SRBS541SRBS771S

240 VOLT PART NUMBERS
RBS1610S, RBS2110SRBS2910S
RBS4210S, RBS5410SRBS7710S

Watlow RGS Tubular Series WATROD Elements

LIGHT OILS, GREASES, HEAT TRANSFER OILS
23 Watts per Sq. Inch, Steel Sheath, .475 Diameter
Sheath Lengths from 23 inches to 157 inches
Wattages from 500 to 5000 (5 kw)

120 VOLT PART NUMBERS
RGS231S, RGS311SRGS391S
RGS451S, RGS541S, RGS691SRGS841S

240 VOLT PART NUMBERS
RGS2310S, RGS3110SRGS3910S, RGS4510S
RGS5410SRGS8410SRGS9910S, RGS13210S, RGS15710S

480 VOLT PART NUMBERS
RGS3911SRGS5411SRGS6911SRGS8411S
RGS9911S, RGS10611SRGS13211SRGS14411SRGS15711S

Watlow RAN & RBN Tubular Series WATROD Elements

AIR HEATING
30 Watts per Sq. Inch, Alloy 800 Sheath, .260 Diameter and .315 Diameter
Sheath Lengths from 20 inches to 100 inches
Wattages from 400 to 3000 (3 kw)

120 VOLT PART RAN NUMBERS
RAN2010S, RAN2510SRAN3010S, RAN3510S, RAN4010S
RAN4510S, RAN5010SRAN5510SRAN6010S, RAN6510S
RAN7010S, RAN7510S, RAN8010S

120 VOLT PART RBN NUMBERS
RBN1510S, RBN2010SRBN2510SRBN3010SRBN3510S
RBN4010S, RBN4510SRBN5010SRBN5510SRBN6010S
RBN6510SRBN7010SRBN7510S, RBN8010S, RBN9010S, RBN10010S

FOR A QUOTE, USE OUR CONTACT US FORMHERE!

Watlow RGN Tubular Series WATROD Elements

PROCESS WATER
48 Watts per Sq. Inch, Alloy 800 Sheath, .475 Diameter
Sheath Lengths from 23 inches to 157 inches
Wattages from 1000 to 9722 (9.7 kw)

120 VOLT PART NUMBERS
RGN231S, RGN301SRGN391S, RGN441S

240 VOLT PART NUMBERS
RGN2310S, RGN3010SRGN3910SRGN4410S
RGN5410SRGN6910SRGN8410SRGN9910S

480 VOLT PART NUMBERS
RGN2311SRGN3011SRGN3911SRGN4411S, RGN5411S
RGN6911SRGN8411SRGN9211SRGN9911SRGN14911S


Watlow RGR Tubular Series WATROD Elements

DEIONIZED WATER, DEMINERALIZED WATER
60 Watts per Sq. Inch, 316 SS Sheath, .475 Diameter
Sheath Lengths from 20 inches to 105 inches
Wattages from 1000 to 8333 (8.3 kw)

120 VOLT PART NUMBERS
RGR201S, RGR261S

240 VOLT PART NUMBERS
RGR2010S, RGR2610SRGR3410SRGR4010S
RGR4610SRGR5710SRGR6810SRGR7910S

480 VOLT PART NUMBERS
RGR2011S, RGR2611SRGR3411SRGR4011S, RGR4711S
RGR4611SRGR5711SRGR6811SRGR7911S, RGR10511S


Watlow RBR Tubular Series WATROD Elements

HOT RUNNER MOLDS
60 Watts per Sq. Inch, 316 SS Sheath, .315 Diameter
Sheath Lengths from 35 inches to 85 inches
Wattages from 1500 to 4500 (.5 kw)

240 VOLT PART NUMBERS
RBR3510S, RBR4410S, RBR5210S, RBR6010S
RBR6910S, RBR7710S, RBR8510S


FOR A QUOTE, USE OUR CONTACT US FORM, HERE!


Sords Electric
216-765-4230
www.sordselectric.com

Watlow WATROD tubular heating elements for industrial applications.