Showing posts with label 100 amp. Show all posts
Showing posts with label 100 amp. Show all posts

Sunday, June 27, 2021

Altech Disconnect Switches from Sords Electric

 Altech UL98 Disconnect Switches for Industry from Sords Electric

FEATURES

  • One design Used in direct and extended handle Applications
  • Enclosed switches are available in Plastic, sheet metal and Stainless
  • Available as rotary switches for extended or direct handle
  • Every design is lockable in the OFF position
  • Switching Mechanism speed is independent from operator
  • Silver Contacts ensure safe and durable operation
  • Horsepower Ratings up to 60
  • 3 and 4 pole
Altech Disconnect Switches for Industry












UL98 Motor Disconnect Switch - Extended

• Every design is lockable in OFF position • Switching mechanism speed is independent from the operator • Silver contacts ensure safe and durable operation

KU360UL98  3 pole 60A @ 600 volts

KU3100UL98  3 pole 100A @ 600 volts

KU460UL98  4 pole 60A @ 600 volts

KU4100UL98  4 pole 100A @ 600 Volts


UL98 Motor Disconnect Switch - Sheet Metal Enclosure

• UL Type 4 • Excellent in harsh weather conditions • Resistant to many chemicals • Corrosion and UV resistant • IEC IP65 Protection Level • Lockable - Defeatable Handle

KET360UL98 Yellow/Red Handle 3 pole 60A @ 600 volts

KET360UL98  Black Handle 3 pole 60A @ 600 volts

KET460UL98 Yellow/Red Handle 4 pole 60A @ 600 volts

KET460UL98  Black Handle 4 pole 60A @ 600 volts

KET3100UL98 Yellow/Red Handle 3 pole 100A @ 600 volts

KET3100UL98  Black Handle 3 pole 100A @ 600 volts

KET4100UL98   Yellow/Red Handle 4 pole 100A @ 600 volts

KET4100UL98   Black Handle 4 pole 100A @ 600 volts


UL98 Motor Disconnect Switch - Stainless Steel Enclosure

• UL Type 4X • Ideal where chemicals are used for cleaning and maintenance such as food processing and breweries • Mining is another application area • Stainless Steel (Grade AISI 316)•Corrosion Resistant • IEC IP65 Protection Level • Lockable - Defeatable Handle

KER360UL98   Yellow/Red Handle 3 pole 60A @ 600 volts

KER360UL98    Black Handle 3 pole 60A @ 600 volts

KER460UL98   Yellow/Red Handle 4 pole 60A @ 600 volts

KER460UL98    Black Handle 4 pole 60A @ 600 volts

KER3100UL98  Yellow/Red Handle 3 pole 100A @ 600 volts

KER3100UL98    Black Handle 3 pole 100A @ 600 volts

KER4100UL98   Yellow/Red Handle 4 pole 100A @ 600 volts

KER4100UL98     Black Handle 4 pole 100A @ 600 volts


UL98 Motor Disconnect Switch - Polycarbonate Enclosure

Can be used locally at the motor • UL Type 4X • IEC IP65 Protection Level • UV resistant • Resistant to many chemicals • Lockable - Defeatable Handle

KEM360UL98     Yellow/Red Handle 3 pole 60A @ 600 volts

KEM360UL98      Black Handle 3 pole 60A @ 600 volts

KEM460UL98     Yellow/Red Handle 4 pole 60A @ 600 volts

KEM460UL98       Black Handle 4 pole 60A @ 600 volts

KEM3100UL98    Yellow/Red Handle 3 pole 100A @ 600 volts

KEM3100UL98     Black Handle 3 pole 100A @ 600 volts

KEM4100UL98    Yellow/Red Handle 4 pole 100A @ 600 volts

KEM4100UL98     Black Handle 4 pole 100A @ 600 volts

Altech UL98 Disconnect Switches





Contact Sords Electric HERE!

Sords Electric

Cleveland, Ohio

216-765-4230

Altech...Disconnects...Altech...Disconnects...Altech...Disconnects

Saturday, March 30, 2019

Selecting Solid State Relays

Sords Electric Sells SSRs or Solid State Relays
Selecting the right relay is important for long life and application efficiency.





BUY SSRs HERE!

Here is guide to selecting and installing (SSRs) Solid State Relays.

A solid state relay or SSR is an electronic device that switches loads on or off when an external voltage or signal is applied to its control terminals. The lack of moving parts in an SSR allows it to switch much faster that electromechanical relays while avoiding the creation for electrical arcs. Solid Sate Relays are also silent, so users won't be subjected to the annoying noise associated with electromechanical relays. Furthermore, because SSRs have no moving parts or contacts that can wear out, SSRs last longer and require less maintenance than electromechanical relays.

SSRs are used in a variety of applications where quick, silent switching is advantageous. Some of these industries include: plastics/rubber, Food and beverage, processing, packaging, HVAC, semiconductor, oil/gas, transportation, conveyors, power or energy systems, printing, laboratory,kiln/oven, lighting, medical/pharmaceutical, and motion control.

How will your solid state relays be mounted/installed?


SSRs are available in a few mooting configurations. Printed circuit board (PCB) mont SSRs are limited in load size due to electric creepage and clearance distance and heat dissipation constraints.
Chassis munt SSRs are often installed to a back panel of an electrical panel but may also mount directly to a metal surface within a machine or appliance. Typically, the SSR can be mounted without a heat sink if the load is un 5 amps or under 8 amps if the mounting surface is an unpainted metal plate. To achieve the desired maximum SSR output rating, a sink sink must be properly sized and installed along with the SSR.

Engineers wo tont want to worry about properly sizing and mooting a heat sink can opt for an SSR with an integrated heat sink. These typically snap directly onto the DIN rail and are ready to wire up and use. Many of the more advanced Ssts, such as those enabling proportional control, are available in this design.  Is it also easier to obtain agency approval with SSRs integrated heat sinks, which are typically cUL listed and carry horse power ratings.

How Many Poles Need to be Switched?


When selecting a Solid State Relay, you will need to know how many polkas  (or lines of voyage) are to be switched to the load.  If your application uses a DC load, you'll need a one pole DC switching SSR. For a single-phase AC load you'll need a one pole AC switching SSR.  For a three phase AC load, you'll need to determine if you want to switch all three poles to the load or if you can get by with only switching 2 poles.  This can be achieved with a two-pole or three-pole three phase switching SSR.

What is Your Load Voltage and Current?


You will need to determine the maximum AC or DC voltage and current for your load. These variables are typically found on the specification of your motor, heater or other electrical device. For AC loads, SSRs usually switch on phase at 120 or 240 VAC or for three phase applications: 208, 240, 480 or 600 VAC.  Also factor in any potential power sags or surges in the application location when determining the minimum and maximum load voltage. DC loads are gong to be powered by DC voltage.
For motors, you will need to know the maximum horse power or kilowatt rainy at the respective voltage of your application. Check for these specs on the motor name plate.

What is the control voltage or input signal to turn the SSR on?


Next you'll need to determine another kind of voltage, the pick-up voltage that is required to energize your load as its turn off voltage (at which your load will de-energize). These are the critical control voltages for your SSR, and are usually found on your loads spec sheet. Unlike electromechanical relays or contractors which typically are controlled by a fixed voltage, SSrs have input ranges either VDC or dual VAC/VDC.
If you wish to proportionally control your load, you'll need some additional specs to choose the proper SSR. Proportional control is typically done with a 0-5, 1-5 or 0-10 VDC input or a 4-20mA control signal. Be sure to consult with a SSR manufacturer to determine the optimum out-put switching type for your load application, as it can get a bit sophisticated. Proportional output types include phase angle, distributed full cycle, burst full cycle, soft start and burst full cycle with soft start.

What is the Ambient temperature where the SSR will be installed or located?


The maximum SSR current rating depends upon the ambient temperature where is will be used and installed. Heightened temperatures can reduce the SSRs current rating.  Any SSRs are mounted on a chassis and require a heat sink t ptomaine their performance. you will need to know the ambient temperature, as well as the mounting orientation upfront, to properly ensure the right type of heat sink is specified.  Highly competent SSR manufacturers provide online tools to help match single or multiple SSRs with the appropriate heat sink. With Din rail mountable SSRs the heat sink is already integrated and the ratings are typically listed on the side of the device or data sheet for various ambient temperatures.  Keep in mind that higher ambient temperatures will require you to de-rate the current rating of the Solid State Relay.


BUY SSRs HERE!



Sords Electric
216-765-4230

Sunday, February 24, 2019

MDI 100 Amp Mercury Relays

Sords Electric Sells 100 Amp Mercury Relays from MDI

Mercury Relays are devices that use Mercury to conduct and electrical circuit to turn on and off an electrical circuit. The Mercury Relays or contactors can switch very quickly and have a very long life. Mercury relays are a preferred method to turning on electrical resistance heating elements. Mercury relays are also excellent in traffic control as they have a very high ambient temperature resistance.

Mercury Relay features:


  • ADVANTAGES OVER ELECTROMECHANICAL AND SOLID STATE RELAYS
    1. Superior Performance and Reliability
      1. Long life
      2. Durable
    2. Compact Size
    3. Low, Predictable Contact Resistance
    4. Reduced RFI for Improved Interface Capability
    5. Handles a Variety of Loads
      1. Increases design flexibility
    6. Rapid On-Off Cycling Capability
      1. Mercury quickly dissipates contact heat
    7. Low Coil Power Requirements
    8. Minimal Derating Due to Higher Ambient Temperatures
    9. Quiet Action
  • DESIGN and CONSTRUCTION
    1. Contacts are within a hermetically sealed steel body
      1. Impervious to adverse conditions
      2. No external arcing
    2. Arcing is in a gaseous atmosphere
      1. Quenches the arc
      2. Extends relay life
    3. Only one moving part (the plunger)
      1. No buttons to pit, weld or burn out
    4. One coil for each set of contacts
      1. Assures consistent switching
      2. Minimizes pull-in variation between contacts
    5. Epoxy encapsulated
      1. Moisture resistant
      2. High dielectric strength
      3. Permanently fixes contacts to coil; eliminating possible misalignment
      4. Helps dissipate heat and noise
      5. Rugged (impact resistant)
  • BENEFITS
    1. Reduction of Operational and Maintenance costs
    2. Increases Utilization and Productivity of Equipment
      1. By reducing down-time
    3. Installation and service is a routine operation
      1. Simple to install
      2. No sophisticated equipment is required
      3. Easy to trouble-shoot




  • MDI Mercury relays come in single pole, double Pole, 3 pole and 4 pole versions and both normally open and normally closed. Normally open are more common for heaters. The voltage rating is for the contractor coil.  All the MDI mercury contractors can switch their rated amperage and up to 600 volts.

    Single Pole MDI 100 Amp Mercury Contactors




    MDI 100NO120A, 100 amp Mercury Contactor, Single Pole, 120vac Coil
    MDI 100NO24A, 100 amp Mercury Contactor, Single Pole, 24vac Coil
    MDI 100NO220A, 100 amp Mercury Contactor, Single Pole, 220vac Coil

    MDI 100NO480A, 100 amp Mercury Contactor, Single Pole, 480vac Coil

    MDI 100NO24D, 100 amp Mercury Contactor, Single Pole, 24vdc Coil

    Double Pole MDI 100 Amp Mercury Contactors



    MDI 2100NO120A, 100 amp Mercury Contactor, Two Pole, 120vac

    MDI 2100NO24A, 100 amp Mercury Contactor, Two Pole, 24vac

    MDI 2100NO220A, 100 amp Mercury Contactor, Two Pole, 220vac

    MDI 2100NO480A, 100 amp Mercury Contactor, Two Pole, 480vac

    MDI 2100NO24D, 100 amp Mercury Contactor, Two Pole, 24vdc

    Three Pole MDI 100 Amp Mercury Contactors



    MDI 3100NO120A, 100 amp Mercury Contactor, Three Pole, 120vac

    MDI 3100NO24A, 100 amp Mercury Contactor, Three Pole, 24vac

    MDI 3100NO220A, 100 amp Mercury Contactor, Three Pole, 220vac

    MDI 3100NO480A, 100 amp Mercury Contactor, Three Pole, 480vac

    MDI 3100NO24D, 100 amp Mercury Contactor, Three Pole, 24vdc

    Four Pole MDI 100 Amp Mercury Contactors







    MDI 4100NO120A, 100 amp Mercury Contactor, Four Pole, 120vac

    MDI 4100NO24A, 100 amp Mercury Contactor, Four Pole, 24vac

    MDI 4100NO220A, 100 amp Mercury Contactor, Four Pole, 220vac

    MDI 4100NO480A, 100 amp Mercury Contactor, Four Pole, 480vac

    MDI 4100NO24D, 100 amp Mercury Contactor, Four Pole, 24vdc

    Contact Sords Electric

    Sords Electric
    216-7656-4230
    www.sordselectric.com

    Thursday, May 31, 2018

    MDI Mercury 35 amp Contactors

    Mercury Displacement Industries 35 AMP Contactors

    Buy here on Sords Electric

    Mercury Displacement Relays are all designed and built to meet the most exacting demands of industry. They have won their high place in the electrical field by doing the tough and tricky jobs that ordinary equipment could at best do in an uncertain manner. They have proved their ability to stand up under the most adverse conditions of temperature, dust and moisture, in all types of applications.
    The MDI Mercury normally closed contactors are designed and manufactured to high quality specifications and the contactors are commonly used in various heating, lighting, and many other industrial applications including high voltage ultraviolet type loads. The contacts are encased in hermetically sealed stainless steel tubes to provide reliable switching for millions of operations. MDI has manufactured this contactor since 1975. It is available in the single, two, three & four pole models.

    Mercury contactors are NOT heat sensitive.  They can operate where others contactors cannot.

    MDI Mercury Contactor









    The Contactors come in single pole, dual pole, three pole and four pole styles.
    Coil voltages are: 
    24vac, 120vac, 208vac, 220vac, 277vac, 480vac,
    6vdc, 12vdc, 24vdc, 48vdc, 125vdc, 250vdc

    • Operate Time: 50 milliseconds
    • Release Time: 80 milliseconds
    • Contacts:
      • 35 AMP @ 600 VAC Resistive
        • or
      • 35 AMP @ 480 VAC General Purpose
    • Contact Resistance: .003 ohm
      • After Cycling Under Load
    • Coil Terminals: #6 Binding Head Screws
    • Load Terminals: 4-14 AWG Compression Type
    • Dielectric Withstand: 2500 VAC RMS
    • Longevity: Millions of Cycles
    • Temperature Range: -35°C to 85°C

    Most Popular units are the:

    335NO120A - 3 pole 120 vac coil
    35NO120A -  1 pole 120 vac coil
    335NO24D -  3 pole 24 vdc coil
    35NO24D  -   1 Pole 24 vdc coil


    www.sordselectric.com
    216-765-4230

    Monday, August 31, 2015

    Carlo Gavazzi RAM1A series SSR's



    Sords Electric sells 
    Carlo Gavazzi RAM1A Solid State Relays
    (Standard Hockey Puck form factor (2x2) with industry standard mounting dimensions)

    Carlo Gavazzi offers a comprehensive range of solid state relays (SSR’s) featuring direct copper bonding technology for increased life and reliability. SSR’s are used extensively in the plastics, packaging, food processing, and HVAC industries - primarily for temperature control. They are the logical replacement for mercury contractors.

    Carlo Gavazzi's solid state relays range includes single phase relays up to 125 amps and 3 phase relays up to 75 amps. They are available with both digital and analogue inputs (4-20 mA or 0-10 V) Furthermore, we also offer a complete range of SSR's with a built-in heatsink.



    The industrial, 1-phase relay with antiparallel thyristor out- put is the most widely used industrial SSR due to its mul- tiple application possibilities. The relay can be used for resistive, inductive and capacitive loads. The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current crosses zero. The instant-on relay with DC control input can be used for phase angle control. The built-in snubber secures transient protection. The LED indicates the status of the control input. The clip-on cover secures touch protection (IP 20). Protected output terminals can handle cables up to 16 mm2. 


    • Zero switching (RAM1A) or instant-on switching (RAM1B) AC Solid State Relay
    • Direct copper bonding (DCB) technology
    • LED indication
    • Clip-on IP 20 protection cover - TOUCH SAFE
    • Self-lifting terminals
    • Housing free of moulding mass
    • 2 input ranges: 3-32 * and 20-280 VAC/22-48VDC
    • Operational ratings: Up to 125AACrms and 690VACrms
    • Blocking voltage: Up to 1600Vp
    • Opto-isolation: > 4000VACrms
    • Integrated overvoltage protection by self
      switching (suffix “Z” option)
    • CE, RoHS compliant
    • cURus, CSA, VDE, CCC 


    The industrial, 1-phase relay with antiparallel thyristor out- put is the most widely used industrial SSR due to its mul- tiple application possibilities. The relay can be used for resistive, inductive and capacitive loads. The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current crosses zero. The instant-on relay with DC control input can be used for phase angle control. The built-in snubber secures transient protection. The LED indicates the status of the control input. The clip-on cover secures touch protection (IP 20). Protected output terminals can handle cables up to 16 mm2. 


    RAM1A23D25
    25 amp Solid State Relay, DC input, 265 volts or less output

    RAM1A23D50
    50 amp Solid State Relay, DC input, 265 volts or less output

    RAM1A23D75
    75 amp Solid State Relay, DC input, 265 volts or less output

    RAM1A23D100
    100 amp Solid State Relay, DC input, 265 volts or less output

    RAM1A23D125
    125 amp Solid State Relay, DC input, 265 volts or less output




    125 amp Solid State Relay, AC input, 42-660 volts output, Built in MOV

    RAM1A60A100
    100 amp Solid State Relay, AC input, 42-660 volts output, Built in MOV

    RAM1A60A75
    75 amp Solid State Relay, AC input, 42-660 volts output, Built in MOV

    RAM1A60A50
    50 amp Solid State Relay, AC input, 42-660 volts output, Built in MOV
    RAM1A60A25
    25 amp Solid State Relay, AC input, 42-660 volts output, Built in MOV

    Call us to order at 800-929-2845 or visit our we site HERE.

    Tuesday, January 31, 2012

    Gavazzi Solid State Relays - Hockey Puck Style

    Carlo Gavazzi Solid State Relays by Sords Electric

    Please note that heat sinks may be needed for these relays if the amperage AND ambient temperatures are too high. A rule of thumb is to use only 80% of the rated amps on a relay of these nature.

    10 amp Solid State Relay, Hockey puck style, DC input, <230 volts output

    10 amp Solid State Relay, Hockey puck style, DC input, <480 volts output

    10 amp Solid State Relay, Hockey puck style, AC input, <230 volts output

    10 amp Solid State Relay, Hockey puck style, AC input, <480 volts output

    25 amp Solid State Relay, Hockey puck style, DC input, <240 volts output

    25 amp Solid State Relay, Hockey puck style, AC input, <240 volts output

    25 amp Solid State Relay, Hockey puck style, DC input, <480 volts output

    25 amp Solid State Relay, Hockey puck style, DC input, <230 volts output, Built in MOV

    25 amp Solid State Relay, Hockey puck style, AC/DC input, <230 volts output, Built in MOV

    Carlo Gavazzi Model RM1A48D25
    25 amp Solid State Relay, Hockey puck style, DC input, <480 volts output, Built in MOV

    25 amp Solid State Relay, Hockey puck style, AC/DC input, <480 volts output, Built in MOV

    25 amp Solid State Relay, Hockey puck style, DC input, <600 volts output, Built in MOV

    25 amp Solid State Relay, Hockey puck style, AC/DC input, <600 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, DC input, <240 volts output

    50 amp Solid State Relay, Hockey puck style, AC input, <240 volts output

    50 amp Solid State Relay, Hockey puck style, DC input, <480 volts output

    50 amp Solid State Relay, Hockey puck style, AC input, <480 volts output

    50 amp Solid State Relay, Hockey puck style, DC input, <230 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, AC/DC input, <230 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, DC input, <480 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, AC/DC input, <480 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, DC input, <600 volts output, Built in MOV

    50 amp Solid State Relay, Hockey puck style, AC/DC input, <600 volts output, Built in MOV

    75 amp Solid State Relay, Hockey puck style, DC input, <480 volts output, Built in MOV

    75 amp Solid State Relay, Hockey puck style, AC/DC input, <480 volts output, Built in MOV

    75 amp Solid State Relay, Hockey puck style, DC input, <600 volts output, Built in MOV

    75 amp Solid State Relay, Hockey puck style, AC/DC input, <600 volts output, Built in MOV

    90 amp Solid State Relay, Hockey puck style, DC input, <480 volts output

    90 amp Solid State Relay, Hockey puck style, AC input, <480 volts output

    100 amp Solid State Relay, Hockey puck style, AC/DC input, <480 volts output, Built in MOV

    100 amp Solid State Relay, Hockey puck style, DC input, <480 volts output, Built in MOV

    25 Amp, Three Phase Relay, AC/DC input, <600 volt output

    55 Amp, Three Phase Relay, AC/DC input, <600 volt output


    Please call Sords Electric with questions. Or email us your Carlo Gavazzi part if it is not listed. Use our Gavazzi Form here!

    800-929-2845