Wednesday, May 26, 2021

OSHA Specifications, Definitions and Standards

OSHA - Occupational Safety and Health Administration

STANDARDS    SPECIFICATIONS    DEFINITIONS

GFCI  ELCI  SAFETY PRODUCTS

GFCI 50 amp Protection Distribution Box p/n 19703R02










OSHA Specifications

OSHA REGULATIONS GROUND FAULT PROTECTION 29CFR1910.304(b)(3)(ii)(A) All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel. Note 1 to paragraph (b)(3)(ii)(A) of this section: A cord connector on an extension cord set is considered to be a receptacle outlet if the cord set is used for temporary electric power. Note 2 to paragraph (b)(3)(ii)(A) of this section: Cord sets and devices incorporating the required ground-fault circuit-interrupter that are connected to the receptacle closest to the source of power are acceptable forms of protection. 29CFR1910.304(b)(3)(ii)(B) Receptacles other than 125 volt, single-phase, 15-, 20-, and 30-ampere receptacles that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel. 29CFR1910.304(b)(3)(ii)(C) Where the ground-fault circuit-interrupter protection required by paragraph (b)(3)(ii)(B) of this section is not available for receptacles other than 125-volt, single-phase, 15-, 20-, and 30-ampere, the employer shall establish and implement an assured equipment grounding conductor program covering cord sets, receptacles that are not a part of the building or structure, and equipment connected by cord and plug that are available for use or used by employees on those receptacles. This program shall comply with the following requirements (2 pages…) 1926.404(b)(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters. 

CORD PROTECTION 29CFR1910.304(b)(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: (viii) Other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment. (7) Mechanical execution of work. Electric equipment shall be installed in a neat and workmanlike manner. 29CFR1910.305(a)(2)(x) Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. 29CFR1910.305(a)(2)(xi) Cable assemblies and flexible cords and cables shall be supported in place at intervals that ensure that they will be protected from physical damage. Support shall be in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage. 1926.403 (b)(1) the employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety equipment shall be determined on the basis of the following considerations: (vii) Other factors which contribute to the practical safeguarding of employees using or likely to come in contact with the equipment. 29CFR1926.405(a)(2)(ii)(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multi-conductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by over-current devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors. 29CFR1926.416(e)(1) Worn or frayed electric cords or cables shall not be used. 


TRC 44700 / 44720 GFCI 30 Amp Series GFCI's














2020 NEC New Standard in GFCI Protection

Article 210.63(A) for HVAC equipment & Article 210.63(B) for indoor service equipment and indoor equipment requiring dedicated space

 HVAC equipment in a basement is currently covered in code requiring basement circuits to be GFCI protected. HVAC equipment located in attics and other tight area is not currently covered by any GFCI requirement. The CMP recognized that many HVAC areas are typically tight working spaces where technicians perform justified energized work (they can’t troubleshoot a de-energized circuit). The 2020 code update assures equipment requiring service has a GFCI protected receptacle outlet that is readily accessible. 

Article 210.8(F) 

Code is updated for ALL outdoor outlets supplied by single phase branch circuits rated 150 volts to ground or less, 50 amps or less. This increased from 20 amps and now extends beyond receptacles to include ALL outlets and includes ALL hard-wired equipment. 

The National Electrical Code (NEC®) requires use of listed products to meet the requirements of various “Articles” within the code. 

We currently have the capability and current products that OEM and installers could use to comply with these changes without changing the electrical panel. Existing in line models can be offered as an optional installation kit by the OEM’s. The OEM could also choose to have an optional factory installed GFCI built into the equipment that would utilize our panel mount version. 

2021 UL 943 GFCI Certification Requirement Changes

WHEN IS IT EFFECTIVE: MAY 5, 2021

PARAGRAPHS AFFECTED 

Paragraphs 5.16 and 6.27 have been revised to include the extension of Auto-monitoring and end of life requirements to ALL types of GFCI’s Paragraphs 6.31.2 (d) and (e) have been revised to improve the auto-monitoring function of permanently connected GFCI’s 

WHAT THE CHANGES MEAN 

The changes to these paragraphs now requires ALL GFCI circuits to be provided with an auto-monitoring function. Prior to this change the auto-monitoring function was only applicable to permanently connected GFCI’s. Now all GFCI’s will be required to have periodic, automatic testing of the devices ability to respond to a ground fault. This test will occur each time the power becomes available to the load terminals and will be initiated within 5 seconds of power on and shall be repeated every three hours. If the auto-monitoring circuit detects a problem the circuit will deny power (trip with inability to reset) or trip with the ability to reset, subject to the next auto-monitoring test cycle. 

**Southwire GFCI products will self test within 1/10th of a second, after power on, and will self test every 17 minutes** 

Reason for the change In layman’s terms, currently, the user has to press the test button on a GFCI device to determine if the GFCI is operational. This is hazardous as many GFCI users do not test the circuit prior to use or during the GFCI life cycle. Auto-monitoring ensures the GFCI is ALWAYS operational against a potential life threatening ground fault event without user intervention. 

DEFINITIONS & STANDARDS 

GFCI 

 Ground Fault Circuit Interrupter is an LCPD specifically intended for the protection of people from shock hazard. A GFCI is a device that will immediately stop the flow of electricity if it senses any voltage loss, whether the loss is through the ground wire or to your body. 

EGFPD 

Equipment Ground-Fault Protective Devices (EGFPD) These devices operate to disconnect the electric circuit from the source supply when the ground-fault current exceeds the ground-fault pick up level marked on the equipment. EGFPS’s are intended to be installed only on grounded alternating-current systems IAW National Electric code. EGFPD’s are intended for use in applications where ground-fault protection of equipment is required. EGFPD’s are not intended to be used in place of GFCI where a GFCI is required by NEC. 

ELCI 

Equipment Leakage Circuit Interrupters are a class of LCPD not considered to be “people protectors,” and are generally only intended for equipment protection. ELCIs are virtually identical with ALCIs with the exception that the trip level is set higher than 6mA. 

ALCI 

Appliance Leakage Current Interrupters are a class of leakage current protection devices closely related to GFCIs. In fact, they share the same limits for trip level and response time. The main difference is that ALCI’s are intended for use only in circuits with a solidly grounded neutral conductor. 

LCDI 

Leakage Current Detection Interrupter cord sets are intended to sense leakage currents flowing between or from conductors of the cord set and interrupt the circuit. 

AFCI 

Arc Fault Circuit Interrupters are designed to mitigate the affect of electrical arcs. Defined by UL 1699 they can be provided as circuit breakers, outlet devices, combination devices, adapters and cord sets. The AFCI must differentiate a normal arc (i.e., power tool, light switch, etc.) from a bad arc (i.e., a parallel fault in the wiring). To avoid nuisance tripping, the trip levels are quite higher and time longer than GFCIs, ALCIs or LCDIs. A cord type AFCI’s maximum trip level is 75A for parallel fault and 5A for a series fault, both of which could be a fire in progress. 

PRCD 

Portable Residual Current Devices are designed for use in international applications and intended to protect people from electrical shock by interrupting the electrical circuit to a load when a fault current exceeds its rated trip level. They are compliant with IEC and NEMA standards, depending upon your country of use, and are available in 120V to 230V versions with 6-30mA trip levels. 

UL STANDARDS 

UL Listed products are used in applications where the product is not an integral part of the manufactured system. UL Listed wire and cable products are intended for use within residential, commercial or industrial buildings. 

OSHA REGULATIONS 

OSHA’s scope of regulation covers three major business areas; the Construction Industry, the Maritime Industry and a third category, General Industry, which covers most other business enterprises except for those in mining and agriculture which are overseen by other government agencies. OSHA’s regulations are Federal Law and are contained in the U.S. Government’s Code of Federal Regulations (CFR). Violations of OSHA regulations can subject companies to legal action and fines. 

NEC (NATIONAL ELECTRICAL CODE) STANDARDS 

The National Electrical Code (NEC®) requires use of listed products to meet the requirements of various “Articles” within the code. 

TRC Southwire HD-Pro High Power GFCIs
24396 001 30 amp, 24542 001 60 amp, 24646 001 30 amp
24672 001 60 amp, 24846 001 30 amp













See our listing of  GFCIs HERE!

Sords Electric
216-765-4230
www.sordselectric.com

OSHA...OSHA...OSHA...OSHA...OSHA

Wednesday, January 27, 2021

Littelfuse - Ground-Fault Ground-Check Monitor

Sords Electric Littelfuse SE-105 / SE-107 Series

Ground-Fault Ground-Check Monitor

For a quote, please contact Sords Electric HERE!

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, use the Littelfuse SE-134C / SE-135. 

Features & Benefits

Adjustable pickup (0.5, 2.0, 4.0 A) Unit can be used on a wide variety of trailing cable applications 

Adjustable time delay(0.1 - 2.0 s)  Adjustable trip delay for quick protection and system coordination 

Harmonic filter Prevents false operation 

Zener-characteristic termination assembly Provides reliable ground-check loop verification 

Fail-safe ground-check circuit  Ensures ground-check circuit remains safe even in the event of equipment failure 

Conformal coating  Additional coating protects circuit boards against harsh environment 

SE-105: Selectable UV- or shunt-trip mode  Provides flexibility for different applications 

SE-107: UV-trip mode only  Eliminates chance of unauthorized change to trip circuit 

Littelfuse SE-105 & SE-107 Ground Fault Monitor

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers
Checking or Interlocking Relay (3GC), Ground Fault (50G/N, 51G/N)  
 
Trip Level Settings
0.5, 2.0, 4.0 A
 
Trip Time Settings
0.1 -1.0 s
 
Contact Operating Mode   
Selectable fail-safe or non-fail-safe (SE-105)  Fail-safe only (SE-107) 
 
Harmonic Filtering >> Standard Feature
 
Reset Button 
Local and remote
 
Output Contacts >> Isolated Form A

Approvals
CSA certified, UL Listed (E340889), C-Tick (Australian)
 
Warranty >> 5 years

Mounting  >> Surface

Part numbers and accessories

 ORDERING NUMBER     Voltage

SE-105                         120 Vac 

SE-105D                     120 Vac/Vdc 

SE-105E                      240 Vac 

SE-107                        120 Vac

SE-107D                    120 Vac/Vdc 

SE-107E                      240 Vac

ACCESSORIES:

1N5339B 
Provides a 5-W ground-check termination between the ground-check wire and ground.
 
SE-TA6-SM
Robust and compact stud-mount 50-W ground-check termination assembly with wire lead; replaces 1N4553B.
 
SE-TA6A Series
50-W ground-check termination assembly with convenient mounting holes and screw terminals. 

RK-102, RK-105, RK-105I
Remote Indication and Reset Assembly Remote indication and reset for the SE-105 and SE-107.  
 
RK-13
Separate ground-fault and ground-check indication contacts for the SE-105 or SE-107; separate ground-fault and resistor-fault indication contacts for the SE-325.
 
PPI-600V
The PPI-600V is a ground-wire device that allows a trailing-cable ground to be monitored independently of the parallel ground path created when trailing-cable-fed equipment is in contact with the earth. It also allows a trailing-cable ground to be monitored in the presence of stray dc and it prevents inter-machine arcing caused by the voltages induced in the cables.

 
For a quote, please contact Sords Electric HERE

Sords Electric
216-765-4230
www.sordselecric.com 

Littelfuse SE-105...Littelfuse SE-107...Littelfuse SE-105...Littelfuse SE-107

Tuesday, June 30, 2020

TRC Digital Power Monitor

Sords Electric Stocks the TRC Digital Power Monitor
Electra Check!  TRC Part Number is AECM20020

Contact Sords Electric HERE!



This compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems. Constantly monitors voltage and grequency indications potential inproper polarity and ground wiring.  Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.

Intallation of the AECM20020 Digital Monitor is for use in a standard 120V/a5A outlet.  It is suitable for continuous or occasional use.  The viewing angle of the LCD display is optimized for viewing at a 12:00 viewing position.  Looking directly at or down at the unit while mounted in a low outlet gives the best viewing contrast.
The voltage is measured is RMS which is much more precise that AC average.  RMS metering is the only method tat can accurately measure all AC power sources.  THE RMS voltage and frequency readings are ideal for monitoring modified sine waves, such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.
Operation
The digital monitor display will alternate between line voltage in RMS and line Frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency.

















Voltage range is 85-150 VAC RMS.
Over voltage arm is at 135 VAC RMS
Frequency range is 40 Hz to 80 Hz
Under frequency is 55 Hz
Power rating is 2 watts
Operating current is .02 amps

Call for pricing on the TRC Voltage Monitor AECM20020
Contact page is HERE!


Sords Electric
216-765-4230
www.sordselectric.com

Friday, April 17, 2020

Sords Electric NEW Website

Sords Electric announces a brand new Website Platform.

We accept VISA, AMEX, M/C, Discover and PayPal

For a quote please contact us HERE!

Brands represented:

AmerimationConvectronicsMDITECO Westinghouse
ATCDanfossMeltricToshiba
AutonicsDiversified ElectronicsPepperl+FuchsTRC
BarksdaleFenwalQ'MarkUnited Electric Controls
BoschJessupRobertshaw Schneider ElectricWatlow
BriskHeatKidde FenwalSSACWeintek
Carlo GavazziLittelfuseStiebel-Eltron 
ChromaloxLovato ElectricTapeswitch 

Parts and Components
Electric Heaters
Strip, Cartridge, Band, Air, Unit, Wall, Radiant, Heating Cable, Drum, Water
Timers - Counters - Time Delay Relays
Current Monitors, Voltage Monitors, Phase Monitors, Voltage Alerts
Power Switching Devices
Contactors, Solid State Relays, SCRs, 
Switches
Proximity, Level, PhotoElectric, Inductive, Capacitance, Vibration, Pressure
Temperature Controls
THERMOSWITCH, Process DIN Controls, Detect-A-Fire Switches
Motors and Drives 
Uninteruptible Power Supplies 
Pin and Sleeve Connectors
HMIs
Ground Fault Circuit Interrupters - GFCIs
For a quote please contact us HERE!
Sords Electric - 216-765-4230

Wednesday, January 8, 2020

Gavazzi Compact Magnetic Sensors

Sords Electric sells Carlo Gavazzi Safety Sensors/Switches

For a quote, Use Our Carlo Gavazzi Form HERE.

CARLO GAVAZZI has launched the MC36C Series Compact Safety Magnetic Sensors, designed for safety-related applications, such as the monitoring of swinging, sliding or removable safety guards, which keep personnel safe from dangerous areas. The Carlo Gavazzi MC36C Series of magnetically-coded REED safety magnetic sensors are the ideal solution to monitor the position of sliding, hinged and removable safety guards, especially in dirty and dusty environments. Thanks to their wide actuation range, the MC36C magnetic sensors are ideally suited for use in applications where great tolerances are required, such as with safety gates or doors which are imprecisely aligned.

Gavazzi MC36C Safety Magnetic Switch

















The Carlo Gavazzi MC36C Series are extremely versatile and can work as standalone or in conjunction with a safety module to reach a safety category 4, according to the EN ISO 13849-1 Standard. These are some of the features which make these sensors extremely flexible to meet various application requirements: compact size (36x26x13mm), output configuration (2 NO or 1 NO and 1 NC), availability with 2m cable or M8 quick disconnect (left or right exit).

·      Assured switching range: 5mm with MC36CM
·      Assured switch-off range: 15mm with MC36CM
·      Operating temperature: -25 to +80°C (-13 to 176°F)
·      Rated operating voltage: 12-24 VAC/VDC
·      Rated operating current: 0.25 A (resistive)
·      Maximum switching load: 6W (resistive)
·      Maximum operating frequency: 100 Hz
·      Optional LED indication
·      Degree of protection: IP67
·      CE and cULus approved

The Carlo Gavazzi MC36C safety magnetic sensors are the best choice for non-contact detection and are suitable to monitor safety gates that prevent the entry of personnel in the vicinity of dangerous machines in motion, such as conveyors, robots, mechanical links, etc.

For a quote, Use Our Carlo Gavazzi Form HERE.


Sords Electric
216-765-4230
www.sordselectric.com

Thursday, November 15, 2018

TRC Southwire 24646-001 30 Amp ELCI/GFCI

Sords Electric Sells the TRC HD-PRO ELCI 24646-001-1


The Technology Research HD Pro 24646 High Power ELCI is designed for Motors, pumps, welders, pressure washers, hoists and other high power devices that need GFCI/ELCI protection. The HD Pro 24646 can be configured for inline or bulk head mounting.

Click Link below to order:
TRC HD-PRO 24646-001 30 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

The Southwire TRC HDPro 24646-001 has 2 feet of cable on both the line side and the load side. When the mA trip leakage point is reached the unit will trip and require a MANUAL reset.  If the primary power is disrupted the 24646 will reset automatically when power is restored or returns to normal.

Southwire TRC 30 Amp  HD-Pro 24646-001 GFCI ELCI




















The TRC HD-Pro Features 

480 volts - Three Phase
30 Amps
4/4 AWG Cord Gauge
Adjustable Trip levels are 6mA, 10mA and 30mA

24646-001 HD-Pro GFCI/ELCI Technical Data

Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: 6 times rated Current (30 Amps)
Ambient Temperature: -20ºC to +40ºC
Insulation Voltage: 1500 VRMS - 1 minute
Power On Indication: Lighted Indicator
Drop Out Voltage: 60% Rated Voltage (480 v)
Reset Type: Automatic (When primary Power is lost)
Connection Type: Flying Leads
NEMA 4 Polymer

See Specifications Sheet HERE!

To be called a GFCI (Ground Fault Circuit Interruptor) the unit needs to trip no higher than 6mA.  Above that the unit becomes an ELCI (Equipment Leakage Circuit Interruptor).

A Ground-fault occurs when there is a break in the low resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injury or death.  The ground-fault circuit interrupter, or GFCI, is a fas acting circuit breaker designed to shut of electric power in the event of a ground fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from the equipment along the circuit conductors. When the amount going differs from the amour retuning by approximately 5 milliamperes (4-6mA), the GFCI trips/interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident.  If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in.  If the grounding conductor is not intact or of low impedance the GFCI may not trip until a person provides a path.  In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful. The most common type of shock is from the Ground Fault. GFCIs also protect against fires, overheating and wire destruction.

TRC HD-PRO 24646-001 30 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

Southwire HD-PRO 24646 GFCI from TRC - 30 amps, 480 volts





















Sords Electric
216-765-4233
www.sordselectric.com


Una pérdida a tierra ocurre cuando hay una ruptura en el camino de resistencia baja para conexión a tierra de una herramienta o un sistema eléctrico. La corriente eléctrica entonces puede tomar una trayectoria alterna a la tierra a través del trabajador, resultando en lesiones serias o la muerte.
El interruptor para circuitos con pérdida a tierra, o GFCI, es un circuito interruptor de energía de acción rápida diseñado para desconectar la energía eléctrica en caso de una pérdida a tierra en un lapso de 140 de segundo. Esto funciona comparando la cantidad de corriente que sale y que regresa del equipo a lo largo de los conductores de circuito. Cuando la cantidad que sale es diferente de la cantidad que regresa por aproximadamente 5 mili-amperios, el GFCI interrumpe la corriente.
El GFCI está clasificado para desconectar la corriente suficientemente rápido para prevenir un incidente eléctrico. Si es instalado y mantenido correctamente, esto pasará tan pronto como el equipo defectuoso es enchufado. Si el conductor de conexión a tierra no está intacto o es de baja impedancia, el GFCI quizás no funcione hasta que una persona le proporcione una trayectoria. En este caso, la persona recibirá una descarga, pero el GFCI debe activarse tan rápidamente que la descarga no sería mortal o dañina.
216-765-4233
www.sordselectric.com

Technology Research Corporation - Southwire 

TRC HD-PRO GFCI ELCI 24646-001 30 amps 480/3/60 volts

Monday, October 26, 2015

Meltric DSN 30 208-220 volt 5 HP OSHA rated Plug


Sords Electric Stocks the Meltric DSN30 deContactor from Meltric. The DSN 30 is ideal for welders, compressors, heaters, pumps, motors, and fans.  All Meltric DSN switch plugs are OSHA rated and can be disconnected and connected under load. The switch also serves as a disconnect switch and meets the requirement for a disconnect switch "in sight" of the application.  Below are the parts for a 30 amp 208/240 wall mount system.


Meltric 30 degree angle with Junction box; part number 61-3A053-080-34
Used with DSN 30, DS 20, DR 30 and DSN24c decontactors/plugs.
UPC  784474562409




Meltric Inlet/plug rated 30A, 208-250 volts, 5HP, 4X; part number 63-38073
DSN30 Male Plug used with DSN30 receptacle below.
UPC 784474545204












Meltric Receptacle/connector rated 30A, 208-250 volts, 5HP, 4X; part number 63-34073
DSN30 Female sleeve/socket used with DSN30 plug above.
UPC 7844745445211









Meltric 61-3A013 Nylon Handle for all 30 amp DSN 30 receptacles or plugs. Accepts cable range .20 - .82. NEMA 4 X handle with weather tight grommet at cable entrance.










216-765-4230
Contact Sords Electric

Sunday, February 17, 2013

Carlo Gavazzi WSS/WSM Wireless Safety System

Sords Electric and Carlo Gavazzi can provide Wireless Industrial door safety System.




Carlo Gavazzi has launched our new Wireless Safety System (WSS / WSM) for industrial automatic doors. The system eliminates the spiral cables between door and door controller, eliminating a weak point in traditional door protection systems.
The WSS / WSM System consists of a main controller (WSM), subcontroller (WSS), and photoelectric safety edge sensors (PB11), and is also compatible with many other safety edge products already on the market. An operating range of 10m (33 ft) between the main controller and subcontroller allows use on large doors.
Each main controller can control up to four subcontrollers. Each subcontroller in turn can monitor two safety edges, or one safety edge and one door-in-door sensor. Thus a total of up to eight doors can be monitored by a single main controller. They are ideally suited for large multi-door warehouses and distribution centers. The main controller is connected to the safety input of the main door or gate control panel which operates the doors. The wireless subcontroller is powered by one to four batteries (user can determine how many batteries they wish to use), for extended operation time of over one year.
The controllers and subcontrollers are fully synchronized and multiplexed, operating on 16 different channels, so no crosstalk interference can occur amongst individual sensors. The system meets all relevant global standards, and complies with all FCC and Canada IC regulations, with cUL and CE approvals for assurance of high quality and safety.



Wireless Entrapment Protection Device (EPD) for Industrial Doors. The system is designed to replace the connection cable between the ESPE (electro-sensitive protective equipment) and the door controller. The sub controller has input for either N.C. ESPE, N.O. 8.2 kΩ ESPE or the Carlo Gavazzi low consumption photoelectric ESPE N.C. contact. The system is designed for high reliability using 2.4 GHz duplex communication between the main controller and sub controller. The main controller can handle up to 4 sub modules i.e. one system can handle 8 ESPEs. The sub controller is activated by a test signal from the main controller and stays active during the period of time set at the main controller up to 80 seconds.

• Wireless Entrapment Protection Device for Industrial Doors
• Input for two ESPE (electro-sensitive protective equipment)
• Replaces cable between Door controller and ESPE 
• Input for door-in-door sensor 
• Output ESPE: 1 x SPST NC, 1 x SPST NO (8,2kΩ) • Output low battery: 1 x SPST NC contact
• 2,4 GHz duplex communication 
• Built-in antenna 
• IP66 ratings

Main Controller  WSM 2 B A 2 D24
Sub Controller   WSS 2 B A 2 BAT
Emitter    PB 11 CNT 15 WE
Receiver  PB 11 CNT 15 WR


Call Sords Electric at 216-765-4230 for more information or to order or use our Contact form HERE!
www.sordselectric.com
info@sordselectric.com