Littelfuse SE-134C Series - Ground-Fault Ground-Check Monitor

Littelfuse SE-134C and SE-135 Ground Fault Monitor

The Littelfuse SE-134C/SE-135 is a microprocessor-based, combination ground-wire monitor and ground-fault relay for resistance-grounded or solidly grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The Littelfuse SE-134C/SE-135 is field proven in monitoring trailing cables on large mobile equipment such as drag-lines, mining shovels, shore-to-ship power cables, dock-side cranes, stacker-reclaimers, submersible pumps, and portable conveyors.

To get a quote, please click HERE!

Features & Benefits

Adjustable pickup (0.5 - 12.5 A for SE-CS10)(2 - 50 A for SE-CS40) 
Unit can be used on a wide variety of trailing cable applications 
 
Adjustable time delay(0.1 - 2.5 s) 
Adjustable trip delay for quick protection and system coordination 
 
Output contacts 
Separate annunciation of ground-fault and ground-check faults
 
Ground-check LED indication 
Indication of open or short ground-check wire makes it easier to find faults
 
CT-loop monitoring
Alarms when CT is not connected
 
High-induced-ac rejection 
Makes unit suitable for applications with high voltages and long cables 
 
DFT (Harmonic) filter 
Prevents false operation
 
Zener-characteristic termination assembly 
Provides reliable ground-check loop verification 
 
Fail-safe circuits 
Ensures ground-check and ground-fault circuits remain safe even in the event of equipment failure 
 
Conformal coating 
Additional coating protects circuit boards against harsh environment 
 
XGC option
Increases maximum cable length for ground-check monitoring (10 km typical)

 

Littelfuse Ground Fault Check Monitor - SE-134C & SE-135

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers     Checking or Interlocking Relay (3GC), Ground fault (50G/N, 51G/N)

Input Voltage   65-265 V ac; 85-275 V dc; 18-72 V dc 

Dimensions   H 213 mm (8.4"); W 99 mm (3.9"); D 132 mm (5.2"); 

Trip Level Settings   0.5-12.5 A for SE-CS10, 2 - 50 A for SE-CS40 

Trip Time Settings   0.1-2.5 s 

Contact Operating Mode   Selectable fail-safe or non-fail-safe

Harmonic Filtering   Standard feature 

Test Button     Standard feature 

Reset Button   Standard feature

Output Contacts   Isolated Form A and Form B, Two Form C 

Approvals    CSA certified, UL Listed (E340889), RCM (Australia)(3), CE(3) 

Conformally Coated    Standard feature 

Warranty   5 years 

Mounting   Panel, Surface  

GC Trip Resistance   28 Ω (Standard), 45Ω (XGC Option)

Accessories

SE-CS10 or SE-CS40 Series Ground-Fault Current Transformer 
Required zero-sequence current transformer detects ground-fault current.
 
SE-TA6A Series, SE-TA12A Series Termination Assembly 
Required termination assembly; temperature compensated.
 
Part Numbers:
Littelfuse SE-134C00  120/240 AC/DC 
Littelfuse SE-134C10  24/48 VDC
Littelfuse SE-134CXGC00  120/240 AC/DC
Littelfuse SE-134CXGC10  24/48 VDC 
Littelfuse SE-13500  120/240 AC/DC
Littelfuse SE-135XGC00  120/240 AC/DC
Littelfuse SE-13503  120/240 AC/DC & Ethernet
Littelfuse SE-135XGC03  120/240 AC/DC & Ethernet
Littelfuse SE-13510  24/48 VDC
Littelfuse SE-135XGC10  24/48 VDC
Littelfuse SE-13513  24/48 VDC & Ethernet
Littelfuse SE-135XGC13  24/48 VDC & Ethernet

To get a quote, please click HERE!

Sords Electric
216-765-4230

Littelfuse SE-134C...Littelfuse SE-135...Littelfuse SE-134C...Littelfuse SE-135

Wednesday, January 27, 2021

Littelfuse - Ground-Fault Ground-Check Monitor

Sords Electric Littelfuse SE-105 / SE-107 Series

Ground-Fault Ground-Check Monitor

For a quote, please contact Sords Electric HERE!

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, use the Littelfuse SE-134C / SE-135. 

Features & Benefits

Adjustable pickup (0.5, 2.0, 4.0 A) Unit can be used on a wide variety of trailing cable applications 

Adjustable time delay(0.1 - 2.0 s)  Adjustable trip delay for quick protection and system coordination 

Harmonic filter Prevents false operation 

Zener-characteristic termination assembly Provides reliable ground-check loop verification 

Fail-safe ground-check circuit  Ensures ground-check circuit remains safe even in the event of equipment failure 

Conformal coating  Additional coating protects circuit boards against harsh environment 

SE-105: Selectable UV- or shunt-trip mode  Provides flexibility for different applications 

SE-107: UV-trip mode only  Eliminates chance of unauthorized change to trip circuit 

Littelfuse SE-105 & SE-107 Ground Fault Monitor

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers
Checking or Interlocking Relay (3GC), Ground Fault (50G/N, 51G/N)  
 
Trip Level Settings
0.5, 2.0, 4.0 A
 
Trip Time Settings
0.1 -1.0 s
 
Contact Operating Mode   
Selectable fail-safe or non-fail-safe (SE-105)  Fail-safe only (SE-107) 
 
Harmonic Filtering >> Standard Feature
 
Reset Button 
Local and remote
 
Output Contacts >> Isolated Form A

Approvals
CSA certified, UL Listed (E340889), C-Tick (Australian)
 
Warranty >> 5 years

Mounting  >> Surface

Part numbers and accessories

 ORDERING NUMBER     Voltage

SE-105                         120 Vac 

SE-105D                     120 Vac/Vdc 

SE-105E                      240 Vac 

SE-107                        120 Vac

SE-107D                    120 Vac/Vdc 

SE-107E                      240 Vac

ACCESSORIES:

1N5339B 
Provides a 5-W ground-check termination between the ground-check wire and ground.
 
SE-TA6-SM
Robust and compact stud-mount 50-W ground-check termination assembly with wire lead; replaces 1N4553B.
 
SE-TA6A Series
50-W ground-check termination assembly with convenient mounting holes and screw terminals. 

RK-102, RK-105, RK-105I
Remote Indication and Reset Assembly Remote indication and reset for the SE-105 and SE-107.  
 
RK-13
Separate ground-fault and ground-check indication contacts for the SE-105 or SE-107; separate ground-fault and resistor-fault indication contacts for the SE-325.
 
PPI-600V
The PPI-600V is a ground-wire device that allows a trailing-cable ground to be monitored independently of the parallel ground path created when trailing-cable-fed equipment is in contact with the earth. It also allows a trailing-cable ground to be monitored in the presence of stray dc and it prevents inter-machine arcing caused by the voltages induced in the cables.

 
For a quote, please contact Sords Electric HERE

Sords Electric
216-765-4230
www.sordselecric.com 

Littelfuse SE-105...Littelfuse SE-107...Littelfuse SE-105...Littelfuse SE-107

Sunday, October 6, 2013

High Power GFCI by TRC and Southwire


Technology Research High Power HD-Pro Ground Fault Interrupters from Sords Electric


TRC HD-Pro Southwire High Power GFCI/ELCI Ground Fault 







With the  TRC HD-PRO Series heavy duty, high power ground fault interrupters (GFCIs) you can feel safe around electrical equipment used in wet environments.  Single and three phase models are available for pumps, motors, welders, pressure washers, portable conveyers, hoists, mining tools and a host of high powered machinery.  All HD-PRO models automatically reset after interruption and restoration of power, but will trip on detection of hazardous ground fault conditions.
TRC Hd-Pro GFCI's are available in 120V, 30A to 600V, 100A.
TRC engineered HD-PRO models with an adjustable trip level selector, HD-PRO 6.10.30 and HD-PRO 10.30.50.  This unique design allows the flexibility to select and lock in a trip level of 6, 10 or 30mA, or 10, 30 or 50mA, customizing each model for the specific type of equipment to maximize protection while avoiding unwanted tripping.


































TRC engineers designed the HD-PRO models specifically for high current, rugged environments and these models are field-proven in all kinds of tough applications. The entire HD-PRO family (120V/30A to 600V/80A) is designed to trip within 25 milliseconds after ground fault detection at an adjustable selected trip level of 6, 10 or 30 mA.
Before the development of the HD-PRO Series, facilities with high current – high voltage equipment or three phase systems employed expensive ground fault breakers at the source of the branch circuit, or went without ground fault protection, leaving personnel and equipment unprotected.
Circuit breakers can withstand high current levels but have short mechanical lives and were not designed for switching duty. Localized ground faults, with circuit breakers, either shut down the whole branch circuit or were overloaded because the available devices were not portable and were often too costly.
The HD-PRO Series utilizes contactors that are fully rated for motor switching demands. In addition to being far less expensive than three phase breakers, the HD-PRO models protect expensive high current – high voltage equipment at the point of use while offering substantial shock protection for personnel.
TRC is an internationally recognized leader in electrical safety products that protect equipment, prevent electrical fires and protect against electrocution and serious injury from electrical shock.

High Power/ Heavy Duty GFCI's and ELCI's protect Motors, Pumps, Welders, Portable Conveyors, Freight Lifts, Pressure Washers

Heavy Duty - High Power ELCIs - 30A and 60A

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. 
The TRC 24140 and 24500 have 2’ of cable on both line and load side. Will remain reset on power restoration following disruption of primary power.

24140 002 ELCI Volts/Amps: 240V/30A Cord Gauge: 10/4 AWG Trip Level: 10 mA Single Phase NEMA 4 Housing

24500 006 ELCI Volts/Amps: 208-240V/30A Cord Gauge: 10/4 AWG Trip Level: 10 mA Three Phase NEMA 4 Housing 


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds.  NEMA 4 polymer Enclosure
The TRC 24520, 24530 and 25560 have 2’ of cable on both line and load side. To prevent equipment startup after ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.

24520 001  Volts/Amps: 120V/60A  Cord Gauge: 4/3 AWG  Trip Level: 10 mA  Single Phase

24530 001  Volts/Amps: 240V/60A  Cord Gauge: 4/4 AWG  Trip Level: 10 mA  Three Phase

25560 001  Volts/Amps: 380V/60A  Cord Gauge: 4/4 AWG  Trip Level: 30 mA  Three Phase


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds.  NEMA 4 polymer Enclosure
The TRC 24396, 24542, 24646, 24672 and 24846 have 2’ of cable on both line and load side. To prevent equipment startup after GFCI/ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enables trip level selection and locking at a trip level with key removal.

24396 001 Volts/Amps: 277V/30A Cord Gauge: 10/3 AWG TripLevel:6,10 & 30 mA Single Phase

24542 001 Volts/Amps: 208-240V/60A  Cord Gauge: 4/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24646 001 Volts/Amps: 480V/30A Cord Gauge: 10/4 AWG TripLevel:6,10 & 30 mA Three Phase

24672 001 Volts/Amps: 480V/60A  Cord Gauge: 4/4 AWG  TripLevel:6,10 &30 mA  Three Phase

24846 001 Volts/Amps: 208-240V/30A  Cord Gauge: 8/5 AWG  TripLevel:6,10 & 30 mA  Three Phase


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds.  NEMA 4 polymer Enclosure
The TRC 24396, 24542, 24646, 24672 and 24846 have 2’ of cable on both line and load side. To prevent equipment startup after GFCI/ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enables trip level selection and locking at a trip level with key removal.

24736 001 Volts/Amps: 480V/100A  Cord Gauge: 2/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24786 001  Volts/Amps: 208-240V/80A  Cord Gauge: 4/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24796 001  Volts/Amps: 480V/80A  Cord Gauge: 4/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24946 003  Volts/Amps: 600V/60A  Cord Gauge: 4/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24992 001  Volts/Amps: 600V/80A  Cord Gauge: 4/4 AWG  TripLevel:6,10 & 30 mA  Three Phase

24994 001  Volts/Amps: 600V/100A  Cord Gauge: 2/4 AWG  TripLevel:6,10 & 30 mA  Three Phase


















Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds.  NEMA 4 16 gauge steel enclosure.
To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power. 
Key enables trip level selection and locks at a trip level with key removal.

For the below units, please call Sords Electric or use our Parts Form Request to receive a quotation

44110 012  EGFPD (Equipment Ground Fault Protection Devices)  CSA Listed
Volts/Amps: 208-240V/30A TripLevel:10,30 & 50 mA  Three Phase

44140 012  EGFPD (Equipment Ground Fault Protection Devices)  CSA Listed
Volts/Amps: 208-240V/60A TripLevel:10,30 & 50 mA  Three Phase

44120 012 EGFPD (Equipment Ground Fault Protection Devices)  CSA Listed
Volts/Amps: 480V/30A TripLevel:10,30 & 50 mA  Three Phase

44130 012 EGFPD (Equipment Ground Fault Protection Devices)  CSA Listed
Volts/Amps: 480V/60A TripLevel:10,30 & 50 mA  Three Phase

44610 001  GFCI / ELCI 
Volts/Amps: 208-240V/30A TripLevel:10,30 & 30 mA  Three Phase

44640 001  GFCI / ELCI 
Volts/Amps: 208-240V/60A TripLevel:10,30 & 30 mA  Three Phase

44620 001 GFCI / ELCI 
Volts/Amps: 480V/30A TripLevel:10,30 & 30 mA  Three Phase

44630 001 GFCI / ELCI 
Volts/Amps: 480V/60A TripLevel:10,30 & 30 mA  Three Phase

Why use Ground Fault:

A “Ground Fault” is a dangerous electrical condition where current flows unintentionally between a live conductor and ground. A severe or fatal electric shock can occur when a user touches the pressure washer if the machine is ungrounded. This could happen if the power cord to extension cord connections become wet or a fault exists within the pressure washer’s sophisticated electrical system. GFCI’s prevent possible electrocution and equipment damage due to electrical malfunction. Once the GFCI trips, the power is interrupted, stopping the pressure washer power and making it electrically safe for people and preventing costly equipment damage.

Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Minimum ground fault, GFCI, protection can be incorporated into the main power disconnect device and could be considered adequate for the entire system. However, in such a design, any downstream ground fault could trip the main protective device resulting in a complete substation power outage. The NEC's purpose, in its own words, is "the practical safeguarding of persons and property…but not necessarily efficient, convenient, or …for good service…" (Article 90.1A, B). In other words, system reliability is left to common sense and good engineering design practices. For this reason ground fault, GFCI, protection of the circuit may be highly desirable and recommended for reliable and continuous operation.
Technology Research Corporation (TRC) is a leading manufacturer of electrical safety products. Based in Clearwater, Florida, TRC designs, develops and manufactures products that prevent electrical fires and protect people and pets from electrocution and serious injury caused by electrical shock.
Use Our TRC parts form as a REQUEST for QUOTE.
800-929-2845
info@sordselectric.com