Wednesday, January 27, 2021

Littelfuse - Ground-Fault Ground-Check Monitor

Sords Electric Littelfuse SE-105 / SE-107 Series

Ground-Fault Ground-Check Monitor

For a quote, please contact Sords Electric HERE!

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, use the Littelfuse SE-134C / SE-135. 

Features & Benefits

Adjustable pickup (0.5, 2.0, 4.0 A) Unit can be used on a wide variety of trailing cable applications 

Adjustable time delay(0.1 - 2.0 s)  Adjustable trip delay for quick protection and system coordination 

Harmonic filter Prevents false operation 

Zener-characteristic termination assembly Provides reliable ground-check loop verification 

Fail-safe ground-check circuit  Ensures ground-check circuit remains safe even in the event of equipment failure 

Conformal coating  Additional coating protects circuit boards against harsh environment 

SE-105: Selectable UV- or shunt-trip mode  Provides flexibility for different applications 

SE-107: UV-trip mode only  Eliminates chance of unauthorized change to trip circuit 

Littelfuse SE-105 & SE-107 Ground Fault Monitor

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers
Checking or Interlocking Relay (3GC), Ground Fault (50G/N, 51G/N)  
 
Trip Level Settings
0.5, 2.0, 4.0 A
 
Trip Time Settings
0.1 -1.0 s
 
Contact Operating Mode   
Selectable fail-safe or non-fail-safe (SE-105)  Fail-safe only (SE-107) 
 
Harmonic Filtering >> Standard Feature
 
Reset Button 
Local and remote
 
Output Contacts >> Isolated Form A

Approvals
CSA certified, UL Listed (E340889), C-Tick (Australian)
 
Warranty >> 5 years

Mounting  >> Surface

Part numbers and accessories

 ORDERING NUMBER     Voltage

SE-105                         120 Vac 

SE-105D                     120 Vac/Vdc 

SE-105E                      240 Vac 

SE-107                        120 Vac

SE-107D                    120 Vac/Vdc 

SE-107E                      240 Vac

ACCESSORIES:

1N5339B 
Provides a 5-W ground-check termination between the ground-check wire and ground.
 
SE-TA6-SM
Robust and compact stud-mount 50-W ground-check termination assembly with wire lead; replaces 1N4553B.
 
SE-TA6A Series
50-W ground-check termination assembly with convenient mounting holes and screw terminals. 

RK-102, RK-105, RK-105I
Remote Indication and Reset Assembly Remote indication and reset for the SE-105 and SE-107.  
 
RK-13
Separate ground-fault and ground-check indication contacts for the SE-105 or SE-107; separate ground-fault and resistor-fault indication contacts for the SE-325.
 
PPI-600V
The PPI-600V is a ground-wire device that allows a trailing-cable ground to be monitored independently of the parallel ground path created when trailing-cable-fed equipment is in contact with the earth. It also allows a trailing-cable ground to be monitored in the presence of stray dc and it prevents inter-machine arcing caused by the voltages induced in the cables.

 