Sords Electric Littelfuse SE-105 / SE-107
Series
Ground-Fault Ground-Check Monitor
For a quote, please contact Sords Electric HERE!
The SE-105/SE-107 is a combination ground-wire monitor
and ground-fault relay for resistance-grounded systems. It
continuously monitors the integrity of the ground conductor
to protect portable equipment from hazardous voltages
caused by ground faults. The SE-105/SE-107 is an excellent
choice for trailing cables 5 kV and under in underground mining
applications. For higher voltages or long-cable applications, use
the Littelfuse SE-134C / SE-135.
Features & Benefits
Adjustable pickup (0.5, 2.0, 4.0 A) Unit can be used on a wide variety of trailing cable applications
Adjustable time delay(0.1 - 2.0 s) Adjustable trip delay for quick protection and system coordination
Harmonic filter Prevents false operation
Zener-characteristic termination assembly Provides reliable ground-check loop verification
Fail-safe ground-check circuit Ensures ground-check circuit remains safe even in the event of equipment failure
Conformal coating Additional coating protects circuit boards against harsh environment
SE-105: Selectable UV- or shunt-trip mode Provides flexibility for different applications
SE-107: UV-trip mode only Eliminates chance of unauthorized change to trip circuit
|
Littelfuse SE-105 & SE-107 Ground Fault Monitor
|
Specifications
IEEE Device Numbers
Checking or Interlocking Relay (3GC), Ground Fault (50G/N, 51G/N)
Trip Level Settings
0.5, 2.0, 4.0 A
Trip Time Settings
0.1 -1.0 s
Contact Operating Mode
Selectable fail-safe or non-fail-safe (SE-105) Fail-safe only (SE-107)
Harmonic Filtering >> Standard Feature
Reset Button
Local and remote
Output Contacts >> Isolated Form A
Approvals
CSA certified, UL Listed (E340889), C-Tick (Australian)
Warranty >> 5 years
Mounting >> Surface
Part numbers and accessories
ORDERING NUMBER Voltage
SE-105 120 Vac
SE-105D 120 Vac/Vdc
SE-105E 240 Vac
SE-107 120 Vac
SE-107D 120 Vac/Vdc
SE-107E 240 Vac
ACCESSORIES:
1N5339B
Provides a 5-W ground-check termination between the ground-check wire and ground.
SE-TA6-SM
Robust and compact stud-mount 50-W ground-check termination assembly with wire lead; replaces 1N4553B.
SE-TA6A Series
50-W ground-check termination assembly with convenient mounting holes and screw terminals.
RK-102, RK-105, RK-105I
Remote Indication and Reset Assembly
Remote indication and reset for the SE-105 and SE-107.
RK-13
Separate ground-fault and ground-check indication contacts for the
SE-105 or SE-107; separate ground-fault and resistor-fault indication
contacts for the SE-325.
PPI-600V
The PPI-600V is a ground-wire device that allows a trailing-cable ground
to be monitored independently of the parallel ground path created when
trailing-cable-fed equipment is in contact with the earth. It also
allows a trailing-cable ground to be monitored in the presence of stray
dc and it prevents inter-machine arcing caused by the voltages induced
in the cables.