Friday, May 28, 2021

Duplex and Quad GFCI Boxes

Quad and Duplex GFCI Boxes from Southwire/TRC

Contact Sords Electric HERE

A ground fault circuit interrupter (GFCI) can help prevent electrocution. If a person’s body starts to receive a shock, the GFCI senses this and cuts off the power before he/she can get injured.

According to the National Electrical Code, a “ground fault” is a conducting connection (whether intentional or accidental) between any electric conductor and any conducting material that is grounded or that may become grounded. Electricity always wants to find a path to the ground. In a ground fault, electricity has found a path to ground, but it is a path the electricity was never intended to be on, such as through a person’s body.

Because of this potential for shock, GFCI protection is used to protect human life.

Note: AFCIs should not be confused with GFCIs. While both AFCIs and GFCIs are important safety devices, they have different functions. AFCIs are intended to address fire hazards; GFCIs address shock hazards.

Southwire TRC Duplex GFCI Box 28438802




15A In-Line GFCI Portable Duplex Box 12/3 Cord Set. P/N 28438802

  • 120V/15A In-Line GFCI Duplex Box 12/3 Cord Set NEMA 5-15P (2) 5-15R
  • Volts/Amps: 120V/15A
  • Cord Gauge: 12/3 AWG
  • NEMA 5-15P & (2) 5-15R
  • Trip Level: 4 - 6 mA
  • cULus Listed
  • Rainproof Rated
TRC Southwire Quad GFCI Box 284688023












20A In-Line GFCI Portable Quad Box 12/3 Cord Set P/N 284688023 - (15 amp version is P/N 28458802 - 5-15P)


  • 120V/20A In-Line GFCI Quad Box 12/3 Cord Set NEMA L5-20P (4) 5-20R
  • Volts/Amps: 120V/20A
  • Cord Gauge: 12/3 AWG
  • NEMA L5-20 Twist-Lock Plug & (4) 5-20 Straight Blade Receptacles
  • Trip Level: 4 - 6 mA
  • cULus Listed
  • Rainproof Rated
GFCI Quad Box 20 amps, 120 volts, 









25080122


20A In-Line GFCI Quad Box 12/3 Cord Set
P/N is 25080122-3 

  • 120V/20A In-Line GFCI Quad Box 12/3 Cord Set NEMA 5-20P (4) 5-20R
  • Volts/Amps: 120V/20A
  • Cord Gauge: 12/3 AWG
  • NEMA 5-20P & (4) 5-20R
  • Trip Level: 4 - 6 mA
  • cULus Listed
  • Rainproof Rated
TRC Quad Box GFCI p/n 14880003












Right Angle GFCI Quad Box 12/3 Cord Set

  • Volts/Amps: 120V/15A
  • Cord Gauge: 12/3 AWG
  • NEMA 5-15P & (4) 5-15R
  • Trip Level: 4 - 6 mA
  • cULus Listed
  • Rainproof Rated
For a Quote, Click  HERE

14880402-3, 26020009-3, 26020004-1, 25080122-3, 
28458802, 25080123-2, 28438802, 28468802, 14880121-1


Sords Electric
216-765-4230
www.sordselectric.com

GFCI...TRC...SOUTHWIRE...GFCI...TRC...SOUTHWIRE

Friday, January 29, 2021

Littelfuse SE-134C Series - Ground-Fault Ground-Check Monitor

Littelfuse SE-134C and SE-135 Ground Fault Monitor

The Littelfuse SE-134C/SE-135 is a microprocessor-based, combination ground-wire monitor and ground-fault relay for resistance-grounded or solidly grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The Littelfuse SE-134C/SE-135 is field proven in monitoring trailing cables on large mobile equipment such as drag-lines, mining shovels, shore-to-ship power cables, dock-side cranes, stacker-reclaimers, submersible pumps, and portable conveyors.

To get a quote, please click HERE!

Features & Benefits

Adjustable pickup (0.5 - 12.5 A for SE-CS10)(2 - 50 A for SE-CS40) 
Unit can be used on a wide variety of trailing cable applications 
 
Adjustable time delay(0.1 - 2.5 s) 
Adjustable trip delay for quick protection and system coordination 
 
Output contacts 
Separate annunciation of ground-fault and ground-check faults
 
Ground-check LED indication 
Indication of open or short ground-check wire makes it easier to find faults
 
CT-loop monitoring
Alarms when CT is not connected
 
High-induced-ac rejection 
Makes unit suitable for applications with high voltages and long cables 
 
DFT (Harmonic) filter 
Prevents false operation
 
Zener-characteristic termination assembly 
Provides reliable ground-check loop verification 
 
Fail-safe circuits 
Ensures ground-check and ground-fault circuits remain safe even in the event of equipment failure 
 
Conformal coating 
Additional coating protects circuit boards against harsh environment 
 
XGC option
Increases maximum cable length for ground-check monitoring (10 km typical)

 

Littelfuse Ground Fault Check Monitor - SE-134C & SE-135

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers     Checking or Interlocking Relay (3GC), Ground fault (50G/N, 51G/N)

Input Voltage   65-265 V ac; 85-275 V dc; 18-72 V dc 

Dimensions   H 213 mm (8.4"); W 99 mm (3.9"); D 132 mm (5.2"); 

Trip Level Settings   0.5-12.5 A for SE-CS10, 2 - 50 A for SE-CS40 

Trip Time Settings   0.1-2.5 s 

Contact Operating Mode   Selectable fail-safe or non-fail-safe

Harmonic Filtering   Standard feature 

Test Button     Standard feature 

Reset Button   Standard feature

Output Contacts   Isolated Form A and Form B, Two Form C 

Approvals    CSA certified, UL Listed (E340889), RCM (Australia)(3), CE(3) 

Conformally Coated    Standard feature 

Warranty   5 years 

Mounting   Panel, Surface  

GC Trip Resistance   28 Ω (Standard), 45Ω (XGC Option)

Accessories

SE-CS10 or SE-CS40 Series Ground-Fault Current Transformer 
Required zero-sequence current transformer detects ground-fault current.
 
SE-TA6A Series, SE-TA12A Series Termination Assembly 
Required termination assembly; temperature compensated.
 
Part Numbers:
Littelfuse SE-134C00  120/240 AC/DC 
Littelfuse SE-134C10  24/48 VDC
Littelfuse SE-134CXGC00  120/240 AC/DC
Littelfuse SE-134CXGC10  24/48 VDC 
Littelfuse SE-13500  120/240 AC/DC
Littelfuse SE-135XGC00  120/240 AC/DC
Littelfuse SE-13503  120/240 AC/DC & Ethernet
Littelfuse SE-135XGC03  120/240 AC/DC & Ethernet
Littelfuse SE-13510  24/48 VDC
Littelfuse SE-135XGC10  24/48 VDC
Littelfuse SE-13513  24/48 VDC & Ethernet
Littelfuse SE-135XGC13  24/48 VDC & Ethernet

To get a quote, please click HERE!

Sords Electric
216-765-4230

Littelfuse SE-134C...Littelfuse SE-135...Littelfuse SE-134C...Littelfuse SE-135

Wednesday, January 27, 2021

Littelfuse - Ground-Fault Ground-Check Monitor

Sords Electric Littelfuse SE-105 / SE-107 Series

Ground-Fault Ground-Check Monitor

For a quote, please contact Sords Electric HERE!

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, use the Littelfuse SE-134C / SE-135. 

Features & Benefits

Adjustable pickup (0.5, 2.0, 4.0 A) Unit can be used on a wide variety of trailing cable applications 

Adjustable time delay(0.1 - 2.0 s)  Adjustable trip delay for quick protection and system coordination 

Harmonic filter Prevents false operation 

Zener-characteristic termination assembly Provides reliable ground-check loop verification 

Fail-safe ground-check circuit  Ensures ground-check circuit remains safe even in the event of equipment failure 

Conformal coating  Additional coating protects circuit boards against harsh environment 

SE-105: Selectable UV- or shunt-trip mode  Provides flexibility for different applications 

SE-107: UV-trip mode only  Eliminates chance of unauthorized change to trip circuit 

Littelfuse SE-105 & SE-107 Ground Fault Monitor

 

 

 

 

 

 

 

 

Specifications

IEEE Device Numbers
Checking or Interlocking Relay (3GC), Ground Fault (50G/N, 51G/N)  
 
Trip Level Settings
0.5, 2.0, 4.0 A
 
Trip Time Settings
0.1 -1.0 s
 
Contact Operating Mode   
Selectable fail-safe or non-fail-safe (SE-105)  Fail-safe only (SE-107) 
 
Harmonic Filtering >> Standard Feature
 
Reset Button 
Local and remote
 
Output Contacts >> Isolated Form A

Approvals
CSA certified, UL Listed (E340889), C-Tick (Australian)
 
Warranty >> 5 years

Mounting  >> Surface

Part numbers and accessories

 ORDERING NUMBER     Voltage

SE-105                         120 Vac 

SE-105D                     120 Vac/Vdc 

SE-105E                      240 Vac 

SE-107                        120 Vac

SE-107D                    120 Vac/Vdc 

SE-107E                      240 Vac

ACCESSORIES:

1N5339B 
Provides a 5-W ground-check termination between the ground-check wire and ground.
 
SE-TA6-SM
Robust and compact stud-mount 50-W ground-check termination assembly with wire lead; replaces 1N4553B.
 
SE-TA6A Series
50-W ground-check termination assembly with convenient mounting holes and screw terminals. 

RK-102, RK-105, RK-105I
Remote Indication and Reset Assembly Remote indication and reset for the SE-105 and SE-107.  
 
RK-13
Separate ground-fault and ground-check indication contacts for the SE-105 or SE-107; separate ground-fault and resistor-fault indication contacts for the SE-325.
 
PPI-600V
The PPI-600V is a ground-wire device that allows a trailing-cable ground to be monitored independently of the parallel ground path created when trailing-cable-fed equipment is in contact with the earth. It also allows a trailing-cable ground to be monitored in the presence of stray dc and it prevents inter-machine arcing caused by the voltages induced in the cables.

 
For a quote, please contact Sords Electric HERE

Sords Electric
216-765-4230
www.sordselecric.com 

Littelfuse SE-105...Littelfuse SE-107...Littelfuse SE-105...Littelfuse SE-107

Tuesday, June 30, 2020

TRC Digital Power Monitor

Sords Electric Stocks the TRC Digital Power Monitor
Electra Check!  TRC Part Number is AECM20020

Contact Sords Electric HERE!



This compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems. Constantly monitors voltage and grequency indications potential inproper polarity and ground wiring.  Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.

Intallation of the AECM20020 Digital Monitor is for use in a standard 120V/a5A outlet.  It is suitable for continuous or occasional use.  The viewing angle of the LCD display is optimized for viewing at a 12:00 viewing position.  Looking directly at or down at the unit while mounted in a low outlet gives the best viewing contrast.
The voltage is measured is RMS which is much more precise that AC average.  RMS metering is the only method tat can accurately measure all AC power sources.  THE RMS voltage and frequency readings are ideal for monitoring modified sine waves, such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.
Operation
The digital monitor display will alternate between line voltage in RMS and line Frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency.

















Voltage range is 85-150 VAC RMS.
Over voltage arm is at 135 VAC RMS
Frequency range is 40 Hz to 80 Hz
Under frequency is 55 Hz
Power rating is 2 watts
Operating current is .02 amps

Call for pricing on the TRC Voltage Monitor AECM20020
Contact page is HERE!


Sords Electric
216-765-4230
www.sordselectric.com

Monday, April 27, 2020

Southwire HD-Pro GFCI 60 Amp, 480/3/60, 24672

Sords Electric Sells the TRC HD-PRO ELCI 24672-001-1

The Technology Research HD Pro 24672 High Power ELCI is designed for Motors, pumps, welders, pressure washers, hoists and other high power devices that need GFCI/ELCI protection. The HD Pro 24672 can be configured for inline or bulk head mounting.

Click Link below to order:
TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

The Southwire TRC HDPro 24672-001 has 2 feet of cable on both the line side and the load side. When the mA trip leakage point is reached the unit will trip and require a MANUAL reset.  If the primary power is disrupted the 24672 will reset automatically when power is restored or returns to normal.

Southwire TRC 60 Amp  HD-Pro 24672-001 GFCI ELCI




















The TRC HD-Pro Features 

480 volts - Three Phase
60 Amps
4/4 AWG Cord Gauge
Adjustable Trip levels are 6mA, 10mA and 30mA

24672-001 HD-Pro GFCI/ELCI Technical Data

Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: 6 times rated Current (30 Amps)
Ambient Temperature: -20ºC to +40ºC
Insulation Voltage: 1500 VRMS - 1 minute
Power On Indication: Lighted Indicator
Drop Out Voltage: 60% Rated Voltage (480 v)
Reset Type: Automatic (When primary Power is lost)
Connection Type: Flying Leads
NEMA 4 Polymer

See Specifications Sheet HERE!

To be called a GFCI (Ground Fault Circuit Interruptor) the unit needs to trip no higher than 6mA.  Above that the unit becomes an ELCI (Equipment Leakage Circuit Interruptor).

A Ground-fault occurs when there is a break in the low resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injury or death.  The ground-fault circuit interrupter, or GFCI, is a fas acting circuit breaker designed to shut of electric power in the event of a ground fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from the equipment along the circuit conductors. When the amount going differs from the amour retuning by approximately 5 milliamperes (4-6mA), the GFCI trips/interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident.  If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in.  If the grounding conductor is not intact or of low impedance the GFCI may not trip until a person provides a path.  In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful. The most common type of shock is from the Ground Fault. GFCIs also protect against fires, overheating and wire destruction.

TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

Southwire HD-PRO 24672 GFCI from TRC - 60 amps, 480 volts





















Sords Electric
216-765-4233
www.sordselectric.com


Una pérdida a tierra ocurre cuando hay una ruptura en el camino de resistencia baja para conexión a tierra de una herramienta o un sistema eléctrico. La corriente eléctrica entonces puede tomar una trayectoria alterna a la tierra a través del trabajador, resultando en lesiones serias o la muerte.
El interruptor para circuitos con pérdida a tierra, o GFCI, es un circuito interruptor de energía de acción rápida diseñado para desconectar la energía eléctrica en caso de una pérdida a tierra en un lapso de 140 de segundo. Esto funciona comparando la cantidad de corriente que sale y que regresa del equipo a lo largo de los conductores de circuito. Cuando la cantidad que sale es diferente de la cantidad que regresa por aproximadamente 5 mili-amperios, el GFCI interrumpe la corriente.
El GFCI está clasificado para desconectar la corriente suficientemente rápido para prevenir un incidente eléctrico. Si es instalado y mantenido correctamente, esto pasará tan pronto como el equipo defectuoso es enchufado. Si el conductor de conexión a tierra no está intacto o es de baja impedancia, el GFCI quizás no funcione hasta que una persona le proporcione una trayectoria. En este caso, la persona recibirá una descarga, pero el GFCI debe activarse tan rápidamente que la descarga no sería mortal o dañina.
216-765-4233
www.sordselectric.com

Technology Research Corporation - Southwire 

TRC HD-PRO GFCI ELCI 24672-001 60 amps 480/3/60 volts