Thursday, May 29, 2014

Robertshaw Vibration Detection

Robertshaw Industrial Division Vibration Malfunction Detection Switches
The Robertshaw VIBRASWITCH from Sords Electric

366A8  366D8  365A-A8  365A-D8

The 366 switch is Nema 4 and the 365 switch is explosion proof.


Robertshaw Vibration Switches and Monitors
What is Vibration?

Vibration is the mechanical motion of a machine or part back and forth from its point of equilibrium.  The term “vibration” may mean different things to different people.  Some may feel it only denotes movement and to others it may suggest both movement and its relative speed per unit time.  To most people, it describes, on an operating machine, a condition indication impending danger when the vibration appears to be exceeding a level previously considered normal. Note the statement, “a level previously considered normal.” All running machines have some amount of normal or inherent vibration. Example: an automobile engine, in perfect condition and tune, does have some level of inherent vibration.  But, when it starts to “run rough”, the vibration level increases and this is the vibration we desire to detect before damage can occur to the engine.

The our most frequently used terms in any discussion n vibration are: Displacement, Velocity, Acceleration and Frequency. Therfore, defining the meanings of these terms is mandatory if an understanding of vibration and it effects is to be had.

DISPLACEMENT:
Also sometimes referred to as amplitude.  This is defined as the magnitude of the movement or motion of the machine or part under study.  The total distance traveled by the vibrating part- from one extreme limit of travel to the opposite extreme limit of travel - is noted as the “Peak to Peak Displacement.” The value of displacement is normally expressed in mils – one thousandth of an inch. Displacement measurement refers then to the “bending” of the moving part.  The greater amount of bend (displacement) the more likely the part is to fail.

VELOCITY:
Speed of movement.  Since the part or machine is moving, it is therefore understood that it is moving at some speed.  Noting a sine wave of the motion, the spped is greatest at the neutral point since at each extreme limit of motion, the part must come to a complete stop before it can change its direction of movement.  It will then increase its speed until it reaches the neutral point when it commences to slowing down prior to reaching the other extreme point of movement. The neutral point – reference to velocity – is referred to as the point of PEAK VELOCITY.  Velocity measurement is expressed in “inches per second peak.”

ACCELERATION:
(What Robertshaw measures)
Acceleration is the first derivative of velocity with respect to time.  On the Sine wave of vibration it is shown that the point of maximum acceleration occur at the extreme limits of travel when the part must stop its movement entirely and restart in the opposite direction.  Therefore, acceleration can be stated as the vibratory “force” being applied to the machine or part.  Large forces of acceleration can occur at hig frequencies even though displacement and velocity of the vibration are small. This can be understood by the fact that acceleration is a function of the displacement and the square of the frequency. This force can result in the breakdown of bearings, lubricant, etc.  Acceleration is sometimes referred to as the measurement or detection of shock. Think of a pre-ignition in one cylinder of an automobile engine.  At the time of pre-ignition, displacement would be very small, velocity is also small but the shock (acceleration) is very high!

FREQUENCY:
The frequency is the number of complete Sine waves the motion of movement a machine of par will make in one unit of time.  Normally, this unit of time is: per minute or per second. Referring to the definition of “displacement,” it was stated that “the greater the amount of bend, the more likely it is to fail.” It can be added that the increasing the rate of bending (the more times per unit of time that the metal is bent), the quicker it will fail.  The “rate” is the frequency. This can also be stated as “the time rate of change of displacement” – or – the first derivative of displacement with respect to time.

SINE WAVE:
The type of vibration produced by a single frequency. This type of vibration rarely, if ever, occurs on an operating machine. Note the Sinusoidal Motion Waveform Figure which is the resultant shape of displacement with respect to time pure harmonic motion-sinusoidal single frequency.



COMPLEX WAVE:
Most operating machines produce vibration waveforms which are non-sinusoidal.  These are called complex periodic waveforms. Recognizing that many frequency components and harmonics are added to produce a given condition of vibration on any particular machine, the resulting motion will assume a complex wave form. The distortion from a pure sine wave is most apparent.  Displacement measurements give little or no information with respect to the harmonic content of the resulting vibratory motion. The complex wave which has a second harmonic with an amplitude 40% as large as the fundamental and a fourth harmonic 20% as large as the fundamental.



Why Monitor Machine Vibration:

The purpose of monitoring vibration is to detect a mechanical malfunction (malfunction detector) as it first begins to develop and wither save an expensive machine or greatly reduce the cost of repairs and down time.  On many machines, dangerous conditions of operation can be corrected IF the machine is stopped before damage is done. Saving from ONE operation of a Vibraswitch can frequently amount to more money than it would cost to equip an entire plant, refinery or pipeline. Thousands of large, electrically driven centrifugal fans or blowers are now protected with circuit breakers on the driving of motors which will respond only to pver current condition of the motor. Others use temperature monitors on anti-friction bearings.  The latter does not respond to unbalance caused by a damaged rotor or accumulated deposits and frequently they respond too late to a failing bearing.  The controls normally installed on large prime movers, for example, respond to all important variable with, in many case, one exception – ACCELERATION due to vibration.  Large machines can and do tear themselves apart without any of the conventional protective devices responding.  When this happens, it is obvious that something is missing in the protective controls.  If the need for vibration protection is so obvious, why isn’t it standard practice for all large machines to have protective devices specified?

Vibration is a difficult quality to measure, comprehend or compare since it is composed of a fundamental, higher harmonics and aperiodic components (transients), all of which vary greatly with different machines and different locations on the same machine. The typical prospective user assumes that the only significant quantity to measure is mils (displacement) and has no idea as to what level would be safe.  The Vibraswitch offers a solution to the machine vibration problem in nearly all cases buy many users do not know of the Robertshaw Vibraswitch.

Many potential users relied on the ability of the operating people to hear any changes in the sound of machines which might reflect mechanical trouble. The dependence on sound was better than nothing but had important disadvantages because sound at the fundamental (low) frequency of rotation is usually inaudible; the human ear is very poor in remembering and comparing sound levels and the sound of a machine Is frequently masked by extraneous noise.  A great disadvantage is that constant operator attendance is required. This is not possible or economical on many machines with automation and remote operation required many places.

How the Robertshaw VIBRASWITCH measure Acceleration:

The Robertshaw detector mechanism consists of an armature suspended on a flexure type pivot and restrained from motion by a permanent magnet acting through a small air gap. A compression spring provides an adjustable force opposing the magnet, and serves as the adjustable set-point calibrated in”G’s.”  The armature acts a s lever; it is forced in one direction by the adjusting spring and balanced by the magnetic orce; as shown in Figure 1.




The Armature is constrained to only one freedom of movement by the flexure pivot composed of two overlapping blocks and a leaf spring loaded in one direction to hold the blocks together as shown in Figure 2.  When the entire assembly is subjected to vibration perpendicular to the base, the peak acceleration times the effective mass of the armature produces an inertial force aided by the spring, which tends to pull the armature away from the stop pin. When the peak acceleration exceeds a pre-selected set point level, the armature leaves the stop pin and moves up to the latch magnet which holds in it the “alarm” (excess vibration) position.
The motion of the armature actuates a snap-action switch which signals that the set-point has been exceeded. The Robertshaw Vibraswitch is a simple mechanical accelerometer with on-off control output!

To get a quote, please use our Robertshaw Parts Form HERE. 

800-929-2845

Wednesday, April 30, 2014

Meltric Wall Mount 30 AMP Plug

Meltric Plug Wall Mount System 30 amp from Sords Electric.

Meltric DeContactors provide a very safe and easy way for providing power for air compressors, welders, heaters and large fans. Below is 240/250 volt wall mount version.  These Meltric deContactors are SWITCH rated, meaning you can disconnect under load.  It short, it can also be an emergency disconnect switch. (Mushroom Pawls Available)






















System includes Junction box, 30 degree angle, female receptacle, male plug and nylon handle.

Above picture shows all but handle.

Meltric Metal Junction Box with angle 61-3A053-080-12

Meltric Receptacle 63-34073  250 volts

Meltric Plug 63-38073   250 volts

Meltric Nylon Handle 61-3A013


Great for Farm Shops, Warehouses, Plant Floors, Green Houses, Garages, Auto Shops, Gas Stations, Bowling Alleys, Restaurants, Dry Cleaners, Breweries and Hotels.

Other voltages available too: 120, 208, 277, 480, 600
Other Amperages available : 20, 60, 100

30 amps parts are usually stock at Sords Electric
Other amperages are 1 week from Meltric.

Meltric parts request form.

www.sordselectric.com
800-929-2845

Sunday, March 30, 2014

Watlow FireRod Cartridge Heaters

Watlow Firerod Cartridge Heaters from Sords Electric


The Watlow FIREROD® cartridge heater revolutionized the heating element industry in 1954 when it was patented as the first swaged cartridge heater. The mechanical procedure of swaging reduces the diameter of the heater by compacting the unit; this directly improves the heat transfer and efficiency of the heater.
Watlow FIRE ROD cartridge heaters are built using only the finest materials and construction methods and are backed with extensive quality assurance programs. With premium materials and tight manufacturing controls, the FIREROD heater provides superior heat transfer, uniform temperatures, resistance to oxidation and corrosion and a long life even at high temperatures.
Alloy 800  Sheath FireRod Cartrdige heaters have a max operating temperature of 1400 F (760C) and a maximum watt density of 400 W/in². Watlow Fire Rod Cartrdige heaters come in 120, 240 and 480 voltages.  Wattages from 25 to 4700 watts.


Applications:
  • Semiconductor chamber heating
  • Semiconductor wafer lead connection
  • Semiconductor wire and die bonding
  • Freeze protection and deicing of equipment in cold climates or applications
  • Humidity control
  • Patient comfort heating used in medical devices
  • Mold die and platen heating
  • Seal bars used in packaging equipment
  • Test sample heating in gas chromatography

Camber
Camber is defined as the maximum deviation of the heater’s centerline from straight. FIREROD camber within allowable tolerances is verified via passage through a cylindrical gauge of specified length and diameter. Normally, slight camber does not present a problem since the heater will flex enough to fit into a straight, close-fit hole.

Component Recognition File Numbers
•  UL® component rated to 240VAC (file number E52951)
•  CSA component rated to 240VAC (file number LR7392) 
•  VDE component rated to 240VAC (file number 10062-4911-0006)
Note: Not all options or combinations of options are covered. UL®, CSA, VDE and CE marking is available upon request.

Watlow FIREROD® catalog page for all sizes:  CLICK HERE!

An assortment of  Watlow Fire Rod Cartridge heaters.

Watlow Firerod Cartridge Heater, 120 volts, 25 Watts, 1/8 diameter, C1E14

Watlow Firerod Cartridge Heater, 120 volts, 50 Watts, 1/8 diameter, C1E13

Watlow Firerod Cartridge Heater, 240 volts, 35 Watts, 1/8 diameter, C1E42

Watlow Firerod Cartridge Heater, 120 volts, 30 Watts, 1/8 diameter, C1J5

Watlow Firerod Cartridge Heater, 120 volts, 60 Watts, 1/8 diameter, C1J6

Watlow Hot Runner Cartridge Heater, 240 volts, 200 Watts, 1/4 diameter, E1JX442A

Watlow Hot Runner Cartridge Heater, 240 volts, 200 Watts, 1/4 diameter, E2AX619A

Watlow Hot Runner Cartridge Heater, 120 volts, 200 Watts, 1/4 diameter, E2JX287A

Watlow Hot Runner Cartridge Heater, 240 volts, 200 Watts, 1/4 diameter, E3AX575A

Watlow Firerod Cartridge Heater, 120 volts, 100 Watts, 1/4 diameter, E1A52

Watlow Firerod Cartridge Heater, 240 volts, 100 Watts, 1/4 diameter, E1A66

Watlow Firerod Cartridge Heater, 120 volts, 200 Watts, 1/4 diameter, E1J42

Watlow Firerod Cartridge Heater, 120 volts, 250 Watts, 1/4 diameter, E2A72

Watlow Firerod Cartridge Heater, 240 volts, 300 Watts, 1/4 diameter, E2A83

Watlow Firerod Cartridge Heater, 120 volts, 250 Watts, 3/8 diameter, G3A52

Watlow Firerod Cartridge Heater, 240 volts, 250 Watts, 3/8 diameter, G3A54

Watlow Firerod Cartridge Heater, 120 volts, 500 Watts, 3/8 diameter, G3A119

Watlow Firerod Cartridge Heater, 240 volts, 500 Watts, 3/8 diameter, G3A120

Watlow Hot Runner Cartridge Heater, 240 volts, 625 Watts, 1/2 diameter, J5AX178B

Watlow Hot Runner Cartridge Heater, 240 volts, 850 Watts, 1/2 diameter, J6JX45C

Watlow Firerod Cartridge Heater, 120 volts, 125 Watts, 1/2 diameter, J1A31

Watlow Firerod Cartridge Heater, 240 volts, 200 Watts, 1/2 diameter, J1E52

Watlow Firerod Cartridge Heater, 120 volts, 200 Watts, 1/2 diameter, J1J59

Watlow Firerod Cartridge Heater, 120 volts, 400 Watts, 1/2 diameter, J2A81

Watlow Firerod Cartridge Heater, 240 volts, 400 Watts, 1/2 diameter, J2A82

Watlow Firerod Cartridge Heater, 120 volts, 500 Watts, 1/2 diameter, J3A110

Watlow Firerod Cartridge Heater, 240 volts, 500 Watts, 1/2 diameter, J3A111

Watlow Firerod Cartridge Heater, 120 volts, 1000 Watts, 1/2 diameter, J3A79

Watlow Firerod Cartridge Heater, 240 volts, 1000 Watts, 1/2 diameter, J4A73

Watlow Firerod Cartridge Heater, 120 volts, 200 Watts, 5/8 diameter, L1E24

Watlow Firerod Cartridge Heater, 120 volts, 250 Watts, 5/8 diameter, L1E27

Watlow Firerod Cartridge Heater, 240 volts, 250 Watts, 5/8 diameter, L1J24

Watlow Firerod Cartridge Heater, 240 volts, 500 Watts, 5/8 diameter, L3A113

Watlow Firerod Cartridge Heater, 240 volts, 750 Watts, 5/8 diameter, L3A71

Watlow Firerod Cartridge Heater, 240 volts, 1000 Watts, 5/8 diameter, L4A71

Watlow Firerod Cartridge Heater, 120 volts, 800 Watts, 5/8 diameter, L5G3

Watlow Firerod Cartridge Heater, 240 volts, 800 Watts, 5/8 diameter, L5G1

Watlow Firerod Cartridge Heater, 240 volts, 500 Watts, 3/4 diameter, N3A12

Watlow Firerod Cartridge Heater, 240 volts, 1000 Watts, 3/4 diameter, N4A15

Watlow Firerod Cartridge Heater, 240 volts, 2000 Watts, 3/4 diameter, N6A22

Watlow Firerod Cartridge Heater, 240 volts, 4000 Watts, 3/4 diameter, N12A25

Watlow Firerod Cartridge Heater, 240 volts, 4500 Watts, 3/4 diameter, N14A21

Watlow Firerod Cartridge Heater, 240 volts, 5000 Watts, 3/4 diameter, N18A15

Watlow Firerod Cartridge Heater, 240 volts, 5500 Watts, 3/4 diameter, N24A13

Buy Watlow Firerod Heaters HERE!

To order via Phone, please call 800-929-2845

Monday, March 3, 2014

Teco Westinghouse's NEW 460 volt N3 Compact Drives

Sords Electric sells Teco's NEW N3 460 volt Variable Frequency Drives


460 volt drives by TECO Westinghouse
View the Teco N3 VFD PDF file HERE.

TECO/Westinghouse’s N3 Series Medium Duty Compact Drive is almost a full featured drive package that can be utilized for most drive applications. This Compact Low Cost versatile AC Drive can operate in constant torque, variable torque, or sensorless vector modes for maximum application flexibility. If you have applications for Fan and Pump Systems, Centrifugal Applications, Larger Conveyors, OEM Products, or Mixers the N3 drive is the right drive for the job.
The Features for the N3 are:
  • IP20 Enclosure: 1 to 10 hp, 230V, 1 to 15 hp, 460V (NEMA 1 Option Kits shipped with units)
  • NEMA 1 Enclosure: 15 hp and Above (230V), 20 hp and Above (460V)
  • Sensorless Vector or V/Hz
  • PID Control,  with Sleep Mode
  • 0 - 400 Hz Speed Range
  • Standard Unit with LED Display
  • LCD Digital Operator (Required for NEMA 4 Keypad Kit)
  • Dynamic Braking Transistor Standard Through 20 hp Models
  • PC Programming Software/ Pocket PC/ Copy Unit
  • RS485 Interface Option
  • RS232 Interface Option
  • Multi-function Digital and Analog Inputs/ Outputs
  • Built-in BACNet Communications
  • UL, cUL, and CE Approved

The TECO/Westinghouse N3 Series AC Drive comes available in the following Voltages.
  • 0.50 to 3 HP, 230V, 50/ 60 Hz, 1-Phase Input with 3 Phase Output
  • 0.50 to 40 HP, 230V, 50/ 60 Hz, 3-Phase
  • 1 to 75 HP, 460V, 50/ 60 Hz, 3-Phase





460 volt drives are listed below




Saturday, March 1, 2014

Teco-Westinghouse New 230 volt N3 Compact Variable Frequency Drive

Sords Electric sells 230 volt TECO's N3 Compact Variable Frequency Drive

230 volt drives by TECO Westinghouse


TECO/Westinghouse’s N3 Series Medium Duty Compact Drive is almost a full featured drive package that can be utilized for most drive applications. This Compact Low Cost versatile AC Drive can operate in constant torque, variable torque, or sensorless vector modes for maximum application flexibility. If you have applications for Fan and Pump Systems, Centrifugal Applications, Larger Conveyors, OEM Products, or Mixers the N3 drive is the right drive for the job.
The Features for the N3 are:
  • IP20 Enclosure: 1 to 10 hp, 230V, 1 to 15 hp, 460V (NEMA 1 Option Kits shipped with units)
  • NEMA 1 Enclosure: 15 hp and Above (230V), 20 hp and Above (460V)
  • Sensorless Vector or V/Hz
  • PID Control,  with Sleep Mode
  • 0 - 400 Hz Speed Range
  • Standard Unit with LED Display
  • LCD Digital Operator (Required for NEMA 4 Keypad Kit)
  • Dynamic Braking Transistor Standard Through 20 hp Models
  • PC Programming Software/ Pocket PC/ Copy Unit
  • RS485 Interface Option
  • RS232 Interface Option
  • Multi-function Digital and Analog Inputs/ Outputs
  • Built-in BACNet Communications
  • UL, cUL, and CE Approved

The TECO/Westinghouse N3 Series AC Drive comes available in the following Voltages.
  • 0.50 to 3 HP, 230V, 50/ 60 Hz, 1-Phase Input with 3 Phase Output
  • 0.50 to 40 HP, 230V, 50/ 60 Hz, 3-Phase
  • 1 to 75 HP, 460V, 50/ 60 Hz, 3-Phase





230 volt drives are listed below






































800-929-2845
www.sordselectric.com



Monday, February 24, 2014

TECO-WESTINGHOUSE EV Micro Drive


The series EV micro drive from Teco-Westinghouse and Sords Electric

TECO/Westinghouse’s EV Series Micro Drive is a power packed  Sensorless Vector Controlled AC Drive that gives you more starting power for Constant Torques applications and yet simplicity and value for Variable Torque applications, all in the same compact IP20 enclosure.
The EV Series drive comes with features that you would only expect in a larger and more expensive drive.
  • PID Control
  • Simple, Full-Featured Operator with Speed Potentiometer
  • 0 to 200 Hz Speed Range
  • 24VDC, 50mA External Sensor Supply Built-in
  • 8 Preset Speeds
  • Multi-function Analog Input/ Output
  • Options Include: RS485, Copy Unit & Remote Keypad
  • Built-in Filter for EMC Compliance (Optional)
  • Din Rail Option
  • UL, cUL, and CE Approved

The TECO/Westinghouse EV Series AC Drive comes available in the following Voltages.
  • ¬ .25 to 1 HP, 115V, 50/60 Hz, 1-Phase Input with 3 Phase Output
  • ¬ .25 to 3 HP, 230V, 50/60 Hz,1-Phase Input with 3 Phase Output
  • ¬ .5 to 3 HP, 230V, 50/60 Hz, 3-Phase
  • ¬ 1 to 3 HP, 460V, 50/60 Hz,3-Phase

To purchase, please click on the part numbers below.
Automatic discounts available at Sords Electric for orders over $500, $1000 and $3000.

TECO JNEV1P2H1, 1/4 HP, 115v

TECO JNEV2P2H1, 1/4 HP, 230v

TECO JNEV1P5H1, 1/2 HP, 115v

TECO JNEV2P5H1, 1/2 HP, 230v

TECO JNEV2P5H3, 1/2 HP, 230v, 3 phase/3 phase

TECO JNEV101H1, 1 HP, 115v

TECO JNEV201H1, 1 HP, 230v

TECO JNEV201H3, 1 HP, 230v, 3 phase/3 phase

TECO JNEV401H3, 1 HP, 460v, 3 phase/3 phase

TECO JNEV202H1, 2 HP, 230v

TECO JNEV202H3, 2 HP, 230v, 3 phase/3 phase

TECO JNEV402H3, 2 HP, 460v, 3 phase/3 phase

TECO JNEV203H1, 3 HP, 230v

TECO JNEV203H3, 3 HP, 230v, 3 phase/3 phase

TECO JNEV403H3, 3 HP, 460v, 3 phase/3 phase











Nema 4 drives below  // chassis drives above.

TECO JNEV2P5H1FN4S, 1/2 HP, 230v

TECO JNEV201H1FN4S, 1 HP, 230v

TECO JNEV401H3FN4S, 1 HP, 460v, 3 phase/3 phase

TECO JNEV202H1FN4S, 2 HP, 230v

TECO JNEV402H3FN4S, 2 HP, 460v, 3 phase/3 phase

TECO JNEV203H1FN4S, 3 HP, 230v

TECO JNEV403H3FN4S, 3 HP, 460v, 3 phase/3 phase


Call Sords Electric for Expert Drive advise.
800-929-2845

www.sordselectric.com