Meltric DSN30 Decontactor Installation Accessories from Sords Electric
Recently Meltric changed the part numbers for most of their accessories.
For a quote please contact us HERE!
DSN30 Poly Handles
Old P/N New P/N
61-3A013-12 512P0N05
61-3A013-34 512P0N07
61-3A013-1 512P0N10
61-3A013 512P0D18
61-3A413 512P0D21
61-3A313 512P6D18
DSN30Angles
Old P/N New P/N
MA2 592M4
61-3A027-601 512M3
MAFS2 92M3FS
MS2 592M0 / 592MO
DSN30 Junction Boxes
Old P/N New P/N
MB312 7T1F0N05
MB334 7T1F0N07
MB31 7T1F0N10
MB3114 7T1F0N12
61-3A053-080-12 712C3N05
61-3A053-080-34 712C3N07
61-3A053-080-1 712C3N10
61-3A053-080-114 712C3N12
61-3A023-12 512B3N05
61-3A023-34 512B3N07
51-BA058 512C7000
59-BA058-12 712C7N05
59-BA058-34 712C7N07
59-BA058-1 712C7N10
59-BA058-114 712C7N12
59-BA058-112 712C7N15
DSN30 Miscellaneous Accessories
Old P/N New P/N
61-3A346 61-3A346 Draw Plates
61-3A426 61-3A426 Protective Cap
61-3A826 61-3A826 Padlockable Cap
SD18 SD18 Screw Driver
Receptacles Inlets
63-34165 63-38165 120 VAC
63-34167 63-38167 120/208 VAC
63-34076 63-38075 125 VAC
63-34076 63-38076 125/250 VAC
63-34162 63-38162 208 VAC
63-34163 63-38163 208 VAC
63-34072 63-38072 250 VAC
63-34073 63-38073 250 VAC
63-34045 63-38045 277 VAC
63-34047 63-38047 277/480 VAC
63-34147 63-38147 347/480 VAC
63-34042 63-38042 480 VAC
63-34043 63-38043 480 VAC
63-34142 63-38142 600 VAC
63-34143 63-38143 600 VAC
For a quote please contact us HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Meltric DSN30..Meltric DSN30..Meltric DSN30..Meltric DSN30..
This blog is dedicated to the discussion of industrial electric switches. All electric switches discussed in this blog are available for sale at our web site: www.sordselectric.com.
Thursday, July 23, 2020
Meltric DSN20 Accessories Cross Reference List
Meltric DSN20 Decontactor Installation Accessories from Sords Electric
Recently Meltric changed the part numbers for their accessories.
For a quote please contact us HERE!
Poly Handles
Old P/N New P/N
61-1A013-12 511P0N05
61-1A013-34 511P0N07
61-1A013-1 511P0N10
61-1A013 511P0D18
61-1A413 511P0D21
61-1A313 511P6D18
Angles
Old P/N New P/N
MA1 591M4
61-1A027-601 511M3
MAFS1 791M3FS
MS1 591M0 / 591MO
Junction Boxes
Old P/N New P/N
MB312 7T1F0N05
MB334 7T1F0N07
MB31 7T1F0N10
MB3114 7T1F0N12
61-1A053-080-12 711C3N05
61-1A053-080-34 711C3N07
61-1A053-080-1 711C3N10
61-1A053-080-114 711C3N12
61-1A023-12 511B3N05
61-1A023-34 511B3N07
51-AA058 511C7000
59-AA058-12 711C7N05
59-AA058-34 711C7N07
59-AA058-1 711C7N10
59-AA058-114 711C7N12
59-AA058-112 711C7N15
Miscellaneous Accessories
Old P/N New P/N
61-1A346 61-1A346 Draw Plates
61-1A426 61-1A426 Protective Cap
61-1A826 61-1A826 Padlockable Cap
SD18 SD18
For a quote please contact us HERE!
Inlet and receptacle part numbers are:
Receptacles Inlets
63-14165 63-18165 120 VAC
63-14167 63-18167 120/208 VAC
63-14076 63-18075 125 VAC
63-14076 63-18076 125/250 VAC
63-14162 63-18162 208 VAC
63-14163 63-18163 208 VAC
63-14072 63-18072 250 VAC
63-14073 63-18073 250 VAC
63-14045 63-18045 277 VAC
63-14047 63-18047 277/480 VAC
63-14147 63-18147 347/480 VAC
63-14042 63-18042 480 VAC
63-14043 63-18043 480 VAC
63-14142 63-18142 600 VAC
63-14143 63-18143 600 VAC
The voltages are color coded to the gaskets on the units.
For a quote please contact us HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Recently Meltric changed the part numbers for their accessories.
For a quote please contact us HERE!
Poly Handles
Old P/N New P/N
61-1A013-12 511P0N05
61-1A013-34 511P0N07
61-1A013-1 511P0N10
61-1A013 511P0D18
61-1A413 511P0D21
61-1A313 511P6D18
Angles
Old P/N New P/N
MA1 591M4
61-1A027-601 511M3
MAFS1 791M3FS
MS1 591M0 / 591MO
Junction Boxes
Old P/N New P/N
MB312 7T1F0N05
MB334 7T1F0N07
MB31 7T1F0N10
MB3114 7T1F0N12
61-1A053-080-12 711C3N05
61-1A053-080-34 711C3N07
61-1A053-080-1 711C3N10
61-1A053-080-114 711C3N12
61-1A023-12 511B3N05
61-1A023-34 511B3N07
51-AA058 511C7000
59-AA058-12 711C7N05
59-AA058-34 711C7N07
59-AA058-1 711C7N10
59-AA058-114 711C7N12
59-AA058-112 711C7N15
Miscellaneous Accessories
Old P/N New P/N
61-1A346 61-1A346 Draw Plates
61-1A426 61-1A426 Protective Cap
61-1A826 61-1A826 Padlockable Cap
SD18 SD18
For a quote please contact us HERE!
Inlet and receptacle part numbers are:
Receptacles Inlets
63-14165 63-18165 120 VAC
63-14167 63-18167 120/208 VAC
63-14076 63-18075 125 VAC
63-14076 63-18076 125/250 VAC
63-14162 63-18162 208 VAC
63-14163 63-18163 208 VAC
63-14072 63-18072 250 VAC
63-14073 63-18073 250 VAC
63-14045 63-18045 277 VAC
63-14047 63-18047 277/480 VAC
63-14147 63-18147 347/480 VAC
63-14042 63-18042 480 VAC
63-14043 63-18043 480 VAC
63-14142 63-18142 600 VAC
63-14143 63-18143 600 VAC
The voltages are color coded to the gaskets on the units.
For a quote please contact us HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Labels:
Connector Protector,
decontactor,
disconnect switch,
DSN,
DSN 20,
DSN20,
Meltric,
pin and sleeve,
Quick Disconnect,
switch
Tuesday, June 30, 2020
TRC Digital Power Monitor
Sords Electric Stocks the TRC Digital Power Monitor
Electra Check! TRC Part Number is AECM20020
Contact Sords Electric HERE!
This compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems. Constantly monitors voltage and grequency indications potential inproper polarity and ground wiring. Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.
Intallation of the AECM20020 Digital Monitor is for use in a standard 120V/a5A outlet. It is suitable for continuous or occasional use. The viewing angle of the LCD display is optimized for viewing at a 12:00 viewing position. Looking directly at or down at the unit while mounted in a low outlet gives the best viewing contrast.
The voltage is measured is RMS which is much more precise that AC average. RMS metering is the only method tat can accurately measure all AC power sources. THE RMS voltage and frequency readings are ideal for monitoring modified sine waves, such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.
Operation
The digital monitor display will alternate between line voltage in RMS and line Frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency.
Voltage range is 85-150 VAC RMS.
Over voltage arm is at 135 VAC RMS
Frequency range is 40 Hz to 80 Hz
Under frequency is 55 Hz
Power rating is 2 watts
Operating current is .02 amps
Call for pricing on the TRC Voltage Monitor AECM20020
Contact page is HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Electra Check! TRC Part Number is AECM20020
Contact Sords Electric HERE!
This compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems. Constantly monitors voltage and grequency indications potential inproper polarity and ground wiring. Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.
Intallation of the AECM20020 Digital Monitor is for use in a standard 120V/a5A outlet. It is suitable for continuous or occasional use. The viewing angle of the LCD display is optimized for viewing at a 12:00 viewing position. Looking directly at or down at the unit while mounted in a low outlet gives the best viewing contrast.
The voltage is measured is RMS which is much more precise that AC average. RMS metering is the only method tat can accurately measure all AC power sources. THE RMS voltage and frequency readings are ideal for monitoring modified sine waves, such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.
Operation
The digital monitor display will alternate between line voltage in RMS and line Frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency.
Voltage range is 85-150 VAC RMS.
Over voltage arm is at 135 VAC RMS
Frequency range is 40 Hz to 80 Hz
Under frequency is 55 Hz
Power rating is 2 watts
Operating current is .02 amps
Call for pricing on the TRC Voltage Monitor AECM20020
Contact page is HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Labels:
amps,
current,
Frequency,
Hertz,
Over Voltage,
Safety,
TRC,
voltage,
Voltage Monitoring
Monday, June 29, 2020
Barksdale C9612 / C9622 Pressure Switches
Sords Electric Sells C9612 and C9622 Barksdale Pressure Switches
Single Setpoint
Barksdale Pressure Switch 250-3000 PSI Range C9612-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9612-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range,C9612-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range,C9612-0-V-CS
Dual Setpoint
Barksdale Pressure Switch 250-3000 PSI Range, C9622-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9622-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range, C9622-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range, C9622-0-V-CS
To order these Barksdale Switches, please Click HERE!
Sords Electric
Cleveland, Ohio
216-765-4230
Visual Indicating Sealed
Piston Pressure Switches
Long life, high cycling, single & dual switches, pressure from 15 - 3,000 psi
Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches offer extremely long life in a robust package, making them the ideal solution to your industrial pressure control needs. Sealed Piston switches are ideal for applications demanding rapid cycling. Available in various pressure ranges from 15 to 3000 psi, sealed piston switches are suitable for use in industrial applications such as hydraulic presses, compactors, and machine tools. All models feature a durable, anodized aluminum enclosure with a tamper proof adjustment screw cover and an integrated 27/32" hole for 1/2" NPT conduit connector, and are rated to NEMA 3 as a standard. Optional terminal boxes allow for ease of electrical connection, and switches are available in both single and dual circuit configurations. For applications requiring a highly accurate switch in a durable package, Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches are the ideal choice.
Piston Pressure Switches
Long life, high cycling, single & dual switches, pressure from 15 - 3,000 psi
Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches offer extremely long life in a robust package, making them the ideal solution to your industrial pressure control needs. Sealed Piston switches are ideal for applications demanding rapid cycling. Available in various pressure ranges from 15 to 3000 psi, sealed piston switches are suitable for use in industrial applications such as hydraulic presses, compactors, and machine tools. All models feature a durable, anodized aluminum enclosure with a tamper proof adjustment screw cover and an integrated 27/32" hole for 1/2" NPT conduit connector, and are rated to NEMA 3 as a standard. Optional terminal boxes allow for ease of electrical connection, and switches are available in both single and dual circuit configurations. For applications requiring a highly accurate switch in a durable package, Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches are the ideal choice.
Applications
- Compactors & balers
- Machine tools
- Lubrication equipment
- Hydraulic presses
- Railroad
- Hydraulic power units
- Compressors
- Utility & power generation
- Metal working application
Applications
- Machine tools
- Hydraulic presses
- Compactors
- Hydraulic power units
- Compressors
Barksdale Pressure Switch 250-3000 PSI Range C9612-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9612-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range,C9612-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range,C9612-0-V-CS
![]() |
| Barksdale C9612 Single Set Point Pressure Switch |
Dual Setpoint
Barksdale Pressure Switch 250-3000 PSI Range, C9622-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9622-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range, C9622-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range, C9622-0-V-CS
![]() |
| Barksdale C9622 Dual Set Point Pressure Switch |
To order these Barksdale Switches, please Click HERE!
Sords Electric
Cleveland, Ohio
216-765-4230
Labels:
Barksdale,
Dual Set,
Indicating,
Piston,
Pressure Switch,
PSI,
Single Set
Monday, May 25, 2020
Barksdale ATEX Pressure Switches
Sords Electric Sells Barksdale ATEX certified Presssure Switches
Barksdale ATEX Pressure switches from vacuum to 15000 PSI (1034 BAR).
To Buy, Click HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Explosion Proof Compact Switch
Compact Vacuum/Pressure Switches
Series 9671X
Compact explosion proof, from 1 - 30 inches Hg. (Vacuum)Series 9681X
Compact explosion proof, low pressure from 1 - 500 psi
Series 9692X
Compact explosion proof, high pressure up to 10,000 psi
![]() |
| Barksdale ATEX Pressure Switch - 9671, 9681, 9692 Series |
Applications
- BOP closing units
- Safety panels
- Pipelines
- Chemical and petrochemical plants
- Pulp and paper mills
- Pump and gas compressors
- Turbines
- Hazardous location dual seal approved for Canada
Accuracy is +/- 2% full scale
Life is 2.5 millions cycles
Wetted Parts:
Process fitting is 316 Stainless Steel
Seals are Viton and Teflon
Enclosure is 316 Stainless or Aluminum
Electric Connection is 1/2 Male conduit or 18 inch WG leads
Electric Rating is 11 Amps (We go to 11!)
SPDT and DPDT available and GOLD contacts (1amp)
Enclosure rating is NEMA 4X, 7 & 9 SS. NEMA 4,7 & 9 Aluminum
Ambient Temperature range -4 to 104ºF
EMI/RFI is EN55011
Vibration is 10g's, 10-500 Hz, MIL-STD 202F
Adjustment is Internal with locking screws
Unit Weight is about 2 pounds
Approvals are:
|
CE 0081, LCIE 08 ATEX 6074X
II 2 G, Ex d IIC T6 Gb
IECEx LCIE 17.0001X
|
|
UL&CSA Approved for use in
hazardous locations Class I,
Groups A,B,C,& D; Class II, Groups E,F,& G (Group A, UL Only)
|
To Buy, Click HERE!
Sords Electric
216-765-4230
www.sordselectric.com
Labels:
ATEX,
BAR,
Barksdale,
Pressure Switch,
PSI
Monday, April 27, 2020
Southwire HD-Pro GFCI 60 Amp, 480/3/60, 24672
Sords Electric Sells the TRC HD-PRO ELCI 24672-001-1
The Technology Research HD Pro 24672 High Power ELCI is designed for Motors, pumps, welders, pressure washers, hoists and other high power devices that need GFCI/ELCI protection. The HD Pro 24672 can be configured for inline or bulk head mounting.Click Link below to order:
TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC
The Southwire TRC HDPro 24672-001 has 2 feet of cable on both the line side and the load side. When the mA trip leakage point is reached the unit will trip and require a MANUAL reset. If the primary power is disrupted the 24672 will reset automatically when power is restored or returns to normal.
![]() |
| Southwire TRC 60 Amp HD-Pro 24672-001 GFCI ELCI |
The TRC HD-Pro Features
480 volts - Three Phase
60 Amps
4/4 AWG Cord Gauge
Adjustable Trip levels are 6mA, 10mA and 30mA
24672-001 HD-Pro GFCI/ELCI Technical Data
Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: 6 times rated Current (30 Amps)
Ambient Temperature: -20ºC to +40ºC
Insulation Voltage: 1500 VRMS - 1 minute
Power On Indication: Lighted Indicator
Drop Out Voltage: 60% Rated Voltage (480 v)
Reset Type: Automatic (When primary Power is lost)
Connection Type: Flying Leads
NEMA 4 Polymer
See Specifications Sheet HERE!
To be called a GFCI (Ground Fault Circuit Interruptor) the unit needs to trip no higher than 6mA. Above that the unit becomes an ELCI (Equipment Leakage Circuit Interruptor).
A Ground-fault occurs when there is a break in the low resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injury or death. The ground-fault circuit interrupter, or GFCI, is a fas acting circuit breaker designed to shut of electric power in the event of a ground fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from the equipment along the circuit conductors. When the amount going differs from the amour retuning by approximately 5 milliamperes (4-6mA), the GFCI trips/interrupts the current.
The GFCI is rated to trip quickly enough to prevent an electrical incident. If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If the grounding conductor is not intact or of low impedance the GFCI may not trip until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful. The most common type of shock is from the Ground Fault. GFCIs also protect against fires, overheating and wire destruction.
TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC
![]() |
| Southwire HD-PRO 24672 GFCI from TRC - 60 amps, 480 volts |
Sords Electric
216-765-4233
www.sordselectric.com
Una pérdida a tierra ocurre cuando hay una ruptura en el camino de resistencia baja para conexión a tierra de una herramienta o un sistema eléctrico. La corriente eléctrica entonces puede tomar una trayectoria alterna a la tierra a través del trabajador, resultando en lesiones serias o la muerte.
El interruptor para circuitos con pérdida a tierra, o GFCI, es un circuito interruptor de energÃa de acción rápida diseñado para desconectar la energÃa eléctrica en caso de una pérdida a tierra en un lapso de 1⁄40 de segundo. Esto funciona comparando la cantidad de corriente que sale y que regresa del equipo a lo largo de los conductores de circuito. Cuando la cantidad que sale es diferente de la cantidad que regresa por aproximadamente 5 mili-amperios, el GFCI interrumpe la corriente.
El GFCI está clasificado para desconectar la corriente suficientemente rápido para prevenir un incidente eléctrico. Si es instalado y mantenido correctamente, esto pasará tan pronto como el equipo defectuoso es enchufado. Si el conductor de conexión a tierra no está intacto o es de baja impedancia, el GFCI quizás no funcione hasta que una persona le proporcione una trayectoria. En este caso, la persona recibirá una descarga, pero el GFCI debe activarse tan rápidamente que la descarga no serÃa mortal o dañina.
216-765-4233www.sordselectric.com
Technology Research Corporation - Southwire
TRC HD-PRO GFCI ELCI 24672-001 60 amps 480/3/60 volts
Labels:
24672,
24672-001,
480/3/60,
60 amps,
Automatic Reset,
GFCI,
High Power,
Southwire,
TRC
Friday, April 17, 2020
Sords Electric NEW Website
Sords Electric announces a brand new Website Platform.
We accept VISA, AMEX, M/C, Discover and PayPal
For a quote please contact us HERE!
Brands represented:
We accept VISA, AMEX, M/C, Discover and PayPal
For a quote please contact us HERE!
Brands represented:
| Amerimation | Convectronics | MDI | TECO Westinghouse |
| ATC | Danfoss | Meltric | Toshiba |
| Autonics | Diversified Electronics | Pepperl+Fuchs | TRC |
| Barksdale | Fenwal | Q'Mark | United Electric Controls |
| Bosch | Jessup | Robertshaw Schneider Electric | Watlow |
| BriskHeat | Kidde Fenwal | SSAC | Weintek |
| Carlo Gavazzi | Littelfuse | Stiebel-Eltron | |
| Chromalox | Lovato Electric | Tapeswitch |
Parts and Components
Electric Heaters
Strip, Cartridge, Band, Air, Unit, Wall, Radiant, Heating Cable, Drum, Water
Timers - Counters - Time Delay Relays
Current Monitors, Voltage Monitors, Phase Monitors, Voltage Alerts
Power Switching Devices
Contactors, Solid State Relays, SCRs,
Switches
Proximity, Level, PhotoElectric, Inductive, Capacitance, Vibration, Pressure
Temperature Controls
THERMOSWITCH, Process DIN Controls, Detect-A-Fire Switches
Motors and Drives
Uninteruptible Power Supplies
Pin and Sleeve Connectors
HMIs
Ground Fault Circuit Interrupters - GFCIs
For a quote please contact us HERE!
Sords Electric - 216-765-4230
Labels:
Carlo Gavazzi,
contactors,
ELCI,
Electric heaters elements,
Fenwal,
GFCI,
level,
mats,
MDI,
PRCD,
proximity switches,
Robertshaw,
Safety,
Safety/Cable Mats,
Southwire,
temperature,
TRC,
Vibration,
WATLOW