Sunday, July 26, 2020

MELTRIC DSN60 ACCESSORY PARTS

Meltric DSN60 Decontactor Installation Accessories from Sords Electric

Recently MELTRIC changed the part numbers for most of their accessories.

See below for OLD vs. NEW part numbers

For a DSN60 MELTRIC quote please contact us HERE!

MELTRIC DSN60 Poly Handles
Meltric DSN Handles for decontactors







Old P/N             New P/N
61-6A013-12     513P0N05 
61-6A013-34     513P0N07
61-6A013-1       513P0N10
61-6A013        513P0D18
61-6A413        513P0D21
61-6A313        513P6D18


MELTRIC DSN60 Angles
Meltric DSN Angles for decontactors








Old P/N          New P/N
MA3                  593M4
61-6A027-601   513M3
MAFS3         793M3FS
MS3        593M0 / 593MO

MELTRIC DSN60 Junction Boxes
Meltric DSN Junction Boxes for decontactors








Old P/N         New P/N
MB312                7T1F0N05
MB334                7T1F0N07
MB31                  7T1F0N10
MB3114              7T1F0N12
61-6A053-080-12      713C3N05
61-6A053-080-34      713C3N07   
61-6A053-080-1        713C3N10
61-6A053-080-114    713C3N12
61-6A023-12          513B3N05
61-6A023-34          513B3N07
51-CA058               513C7000
59-CA058-12         713C7N05
59-CA058-34         713C7N07
59-CA058-1           713C7N10
59-CA058-114       713C7N12
59-CA058-112       713C7N15

DSN60 Miscellaneous Accessories
Meltric DSN decontactor Draw Plates






Old P/N        New P/N
61-6A346     61-6A346  Draw Plates
61-6A426     61-6A426  Protective Cap
61-6A826     61-6A826  Padlockable Cap
SD18            SD18  Screw Driver











Receptacles       Inlets
63-64165           63-68165   120  VAC
63-64167           63-68167   120/208  VAC
63-64076           63-68075   125  VAC
63-64076           63-68076   125/250  VAC
63-64162           63-68162   208  VAC
63-64163           63-68163   208  VAC
63-64072           63-68072   250  VAC
63-64073           63-68073   250  VAC
63-64045           63-68045   277  VAC
63-64047           63-68047   277/480  VAC
63-64147           63-68147   347/480  VAC
63-64042           63-68042   480  VAC
63-64043           63-68043   480  VAC
63-64142           63-68142   600  VAC
63-64143           63-68143   600  VAC       



For a MELTRIC DSN60 quote please contact us HERE!

Sords Electric
216-765-4230
www.sordselectric.com

Meltric DSN60..Meltric DSN60..Meltric DSN60..Meltric DSN60..

Thursday, July 23, 2020

Meltric DSN30 Accessories

Meltric DSN30 Decontactor Installation Accessories from Sords Electric

Recently Meltric changed the part numbers for most of their accessories.

For a quote please contact us HERE!


DSN30 Poly Handles

Old P/N           New P/N
61-3A013-12     512P0N05
61-3A013-34     512P0N07
61-3A013-1       512P0N10
61-3A013        512P0D18
61-3A413        512P0D21
61-3A313        512P6D18


DSN30Angles

Old P/N      New P/N
MA2            592M4
61-3A027-601   512M3
MAFS2          92M3FS
MS2        592M0 /  592MO

DSN30 Junction Boxes

Old P/N          New P/N

MB312                7T1F0N05
MB334                7T1F0N07
MB31                  7T1F0N10
MB3114              7T1F0N12
61-3A053-080-12     712C3N05
61-3A053-080-34     712C3N07  
61-3A053-080-1      712C3N10
61-3A053-080-114    712C3N12
61-3A023-12           512B3N05
61-3A023-34           512B3N07
51-BA058               512C7000
59-BA058-12          712C7N05
59-BA058-34          712C7N07
59-BA058-1             712C7N10
59-BA058-114        712C7N12
59-BA058-112        712C7N15

DSN30 Miscellaneous Accessories

Old P/N        New P/N
61-3A346     61-3A346  Draw Plates
61-3A426     61-3A426  Protective Cap
61-3A826     61-3A826  Padlockable Cap
SD18            SD18  Screw Driver


Receptacles       Inlets
63-34165           63-38165  120 VAC
63-34167           63-38167  120/208 VAC
63-34076           63-38075  125 VAC
63-34076           63-38076  125/250 VAC
63-34162           63-38162  208 VAC
63-34163           63-38163  208 VAC
63-34072           63-38072  250 VAC
63-34073           63-38073  250 VAC
63-34045           63-38045  277 VAC
63-34047           63-38047  277/480 VAC
63-34147           63-38147  347/480 VAC
63-34042           63-38042  480 VAC
63-34043           63-38043  480 VAC
63-34142           63-38142  600 VAC
63-34143           63-38143  600 VAC 


For a quote please contact us HERE!


Sords Electric
216-765-4230
www.sordselectric.com

Meltric DSN30..Meltric DSN30..Meltric DSN30..Meltric DSN30..

Meltric DSN20 Accessories Cross Reference List

Meltric DSN20 Decontactor Installation Accessories from Sords Electric

Recently Meltric changed the part numbers for their accessories.

For a quote please contact us HERE!


Poly Handles

Old P/N             New P/N
61-1A013-12     511P0N05
61-1A013-34     511P0N07
61-1A013-1      511P0N10
61-1A013        511P0D18
61-1A413        511P0D21
61-1A313        511P6D18


Angles

Old P/N               New P/N
MA1                  591M4
61-1A027-601     511M3
MAFS1              791M3FS
MS1               591M0 / 591MO

Junction Boxes


Old P/N             New P/N
MB312                7T1F0N05
MB334                 7T1F0N07
MB31                   7T1F0N10
MB3114                7T1F0N12
61-1A053-080-12      711C3N05
61-1A053-080-34      711C3N07  
61-1A053-080-1        711C3N10
61-1A053-080-114    711C3N12
61-1A023-12         511B3N05
61-1A023-34          511B3N07
51-AA058               511C7000
59-AA058-12          711C7N05
59-AA058-34          711C7N07
59-AA058-1           711C7N10
59-AA058-114        711C7N12
59-AA058-112         711C7N15

Miscellaneous Accessories

Old P/N        New P/N
61-1A346     61-1A346  Draw Plates
61-1A426     61-1A426  Protective Cap
61-1A826     61-1A826  Padlockable Cap
SD18            SD18
  

For a quote please contact us HERE!

Inlet and receptacle part numbers are:

Receptacles       Inlets
63-14165           63-18165  120 VAC
63-14167           63-18167  120/208 VAC
63-14076           63-18075  125 VAC
63-14076           63-18076  125/250 VAC
63-14162           63-18162  208 VAC
63-14163           63-18163  208 VAC
63-14072           63-18072  250 VAC
63-14073           63-18073  250 VAC
63-14045           63-18045  277 VAC
63-14047           63-18047  277/480 VAC
63-14147           63-18147  347/480 VAC
63-14042           63-18042  480 VAC
63-14043           63-18043  480 VAC
63-14142           63-18142  600 VAC
63-14143           63-18143  600 VAC


The voltages are color coded to the gaskets on the units.



For a quote please contact us HERE!

Sords Electric
216-765-4230
www.sordselectric.com

Tuesday, June 30, 2020

TRC Digital Power Monitor

Sords Electric Stocks the TRC Digital Power Monitor
Electra Check!  TRC Part Number is AECM20020

Contact Sords Electric HERE!



This compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems. Constantly monitors voltage and grequency indications potential inproper polarity and ground wiring.  Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.

Intallation of the AECM20020 Digital Monitor is for use in a standard 120V/a5A outlet.  It is suitable for continuous or occasional use.  The viewing angle of the LCD display is optimized for viewing at a 12:00 viewing position.  Looking directly at or down at the unit while mounted in a low outlet gives the best viewing contrast.
The voltage is measured is RMS which is much more precise that AC average.  RMS metering is the only method tat can accurately measure all AC power sources.  THE RMS voltage and frequency readings are ideal for monitoring modified sine waves, such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.
Operation
The digital monitor display will alternate between line voltage in RMS and line Frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency.

















Voltage range is 85-150 VAC RMS.
Over voltage arm is at 135 VAC RMS
Frequency range is 40 Hz to 80 Hz
Under frequency is 55 Hz
Power rating is 2 watts
Operating current is .02 amps

Call for pricing on the TRC Voltage Monitor AECM20020
Contact page is HERE!


Sords Electric
216-765-4230
www.sordselectric.com

Monday, June 29, 2020

Barksdale C9612 / C9622 Pressure Switches

Sords Electric Sells C9612 and C9622 Barksdale Pressure Switches


Visual Indicating Sealed 
Piston Pressure Switches

Long life, high cycling, single & dual switches, pressure from 15 - 3,000 psi

Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches offer extremely long life in a robust package, making them the ideal solution to your industrial pressure control needs. Sealed Piston switches are ideal for applications demanding rapid cycling. Available in various pressure ranges from 15 to 3000 psi, sealed piston switches are suitable for use in industrial applications such as hydraulic presses, compactors, and machine tools. All models feature a durable, anodized aluminum enclosure with a tamper proof adjustment screw cover and an integrated 27/32" hole for 1/2" NPT conduit connector, and are rated to NEMA 3 as a standard. Optional terminal boxes allow for ease of electrical connection, and switches are available in both single and dual circuit configurations. For applications requiring a highly accurate switch in a durable package, Barksdale's Series C9612 and C9622 Sealed Piston Pressure Switches are the ideal choice.


Applications

  • Compactors & balers
  • Machine tools
  • Lubrication equipment
  • Hydraulic presses
  • Railroad
  • Hydraulic power units
  • Compressors
  • Utility & power generation
  • Metal working application

Applications

  • Machine tools
  • Hydraulic presses
  • Compactors
  • Hydraulic power units
  • Compressors

Single Setpoint
Barksdale Pressure Switch 250-3000 PSI Range C9612-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9612-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range,C9612-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range,C9612-0-V-CS


Barksdale C9612 Single Set Point Pressure Switch












Dual Setpoint
Barksdale Pressure Switch 250-3000 PSI Range, C9622-3-V-CS
Barksdale Pressure Switch 125-1500 PSI Range, C9622-2-V-CS
Barksdale Pressure Switch 35-400 PSI Range, C9622-1-V-CS
Barksdale Pressure Switch 15-200 PSI Range, C9622-0-V-CS



Barksdale C9622 Dual Set Point Pressure Switch












To order these Barksdale Switches, please Click HERE!


Sords Electric
Cleveland, Ohio
216-765-4230

Monday, May 25, 2020

Barksdale ATEX Pressure Switches

Sords Electric Sells Barksdale ATEX certified Presssure Switches

Explosion Proof Compact Switch
Compact Vacuum/Pressure Switches

Series 9671X

Compact explosion proof, from 1 - 30 inches Hg. (Vacuum)

Series 9681X

Compact explosion proof, low pressure from 1 - 500 psi

Series 9692X

Compact explosion proof, high pressure up to 10,000 psi

To Buy, Click HERE!

Barksdale ATEX Pressure Switch - 9671, 9681, 9692 Series














Applications

  • BOP closing units
  • Safety panels
  • Pipelines
  • Chemical and petrochemical plants
  • Pulp and paper mills
  • Pump and gas compressors
  • Turbines
  • Hazardous location dual seal approved for Canada
Accuracy is +/- 2% full scale
Life is 2.5 millions cycles
Wetted Parts:
Process fitting is 316 Stainless Steel
Seals are Viton and Teflon
Enclosure is 316 Stainless or Aluminum

Electric Connection is 1/2 Male conduit or 18 inch WG leads

Electric Rating is 11 Amps (We go to 11!)
SPDT and DPDT available and GOLD contacts (1amp)
Enclosure rating is NEMA 4X, 7 & 9 SS.  NEMA 4,7 & 9 Aluminum
Ambient Temperature range -4 to 104ºF
EMI/RFI is EN55011
Vibration is 10g's, 10-500 Hz, MIL-STD 202F
Adjustment is Internal with locking screws
Unit Weight is about 2 pounds

Approvals are:

 CE 0081, LCIE 08 ATEX 6074X 
II 2 G, Ex d IIC T6 Gb
IECEx LCIE 17.0001X

 UL&CSA Approved for use in
hazardous locations Class I, 
Groups A,B,C,& D; Class II, Groups E,F,& G (Group A, UL Only)

Barksdale ATEX Pressure switches from vacuum to 15000 PSI (1034 BAR).

To Buy, Click HERE!

Sords Electric
216-765-4230
www.sordselectric.com

Monday, April 27, 2020

Southwire HD-Pro GFCI 60 Amp, 480/3/60, 24672

Sords Electric Sells the TRC HD-PRO ELCI 24672-001-1

The Technology Research HD Pro 24672 High Power ELCI is designed for Motors, pumps, welders, pressure washers, hoists and other high power devices that need GFCI/ELCI protection. The HD Pro 24672 can be configured for inline or bulk head mounting.

Click Link below to order:
TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

The Southwire TRC HDPro 24672-001 has 2 feet of cable on both the line side and the load side. When the mA trip leakage point is reached the unit will trip and require a MANUAL reset.  If the primary power is disrupted the 24672 will reset automatically when power is restored or returns to normal.

Southwire TRC 60 Amp  HD-Pro 24672-001 GFCI ELCI




















The TRC HD-Pro Features 

480 volts - Three Phase
60 Amps
4/4 AWG Cord Gauge
Adjustable Trip levels are 6mA, 10mA and 30mA

24672-001 HD-Pro GFCI/ELCI Technical Data

Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: 6 times rated Current (30 Amps)
Ambient Temperature: -20ºC to +40ºC
Insulation Voltage: 1500 VRMS - 1 minute
Power On Indication: Lighted Indicator
Drop Out Voltage: 60% Rated Voltage (480 v)
Reset Type: Automatic (When primary Power is lost)
Connection Type: Flying Leads
NEMA 4 Polymer

See Specifications Sheet HERE!

To be called a GFCI (Ground Fault Circuit Interruptor) the unit needs to trip no higher than 6mA.  Above that the unit becomes an ELCI (Equipment Leakage Circuit Interruptor).

A Ground-fault occurs when there is a break in the low resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injury or death.  The ground-fault circuit interrupter, or GFCI, is a fas acting circuit breaker designed to shut of electric power in the event of a ground fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from the equipment along the circuit conductors. When the amount going differs from the amour retuning by approximately 5 milliamperes (4-6mA), the GFCI trips/interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident.  If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in.  If the grounding conductor is not intact or of low impedance the GFCI may not trip until a person provides a path.  In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful. The most common type of shock is from the Ground Fault. GFCIs also protect against fires, overheating and wire destruction.

TRC HD-PRO 24672-001 60 AMP Adjustable (6/10/30 mA) GFCI / ELCI, 480/3 VAC

Southwire HD-PRO 24672 GFCI from TRC - 60 amps, 480 volts





















Sords Electric
216-765-4233
www.sordselectric.com


Una pérdida a tierra ocurre cuando hay una ruptura en el camino de resistencia baja para conexión a tierra de una herramienta o un sistema eléctrico. La corriente eléctrica entonces puede tomar una trayectoria alterna a la tierra a través del trabajador, resultando en lesiones serias o la muerte.
El interruptor para circuitos con pérdida a tierra, o GFCI, es un circuito interruptor de energía de acción rápida diseñado para desconectar la energía eléctrica en caso de una pérdida a tierra en un lapso de 1⁄40 de segundo. Esto funciona comparando la cantidad de corriente que sale y que regresa del equipo a lo largo de los conductores de circuito. Cuando la cantidad que sale es diferente de la cantidad que regresa por aproximadamente 5 mili-amperios, el GFCI interrumpe la corriente.
El GFCI está clasificado para desconectar la corriente suficientemente rápido para prevenir un incidente eléctrico. Si es instalado y mantenido correctamente, esto pasará tan pronto como el equipo defectuoso es enchufado. Si el conductor de conexión a tierra no está intacto o es de baja impedancia, el GFCI quizás no funcione hasta que una persona le proporcione una trayectoria. En este caso, la persona recibirá una descarga, pero el GFCI debe activarse tan rápidamente que la descarga no sería mortal o dañina.
216-765-4233
www.sordselectric.com

Technology Research Corporation - Southwire 

TRC HD-PRO GFCI ELCI 24672-001 60 amps 480/3/60 volts