ATC 356C Series Shawnee Counter

Automatic Timing and Controls 356C Counter from Sords Electric

Click below to purchase:
ATC series 356C350Q30PX, 9999 counts, digital display, 72x72mm, 120V

ATC series 356C350R30PX, 9999 counts, digital display, 72x72mm, 240V

Contact Sords Electric HERE!


The Automatic Timing and Controls Shawnee 356C counter, preceded by the 356A and 356B, is a direct replacement of the ATC 336 Predetermining Counter with the exact functionality but in a smaller 72mm x 72mm package.

ATC Shawnee 356C Predetermining Counter






Features:

Fast, Accurate and Bounce Proof
The repeat accuracy of the ATC 356 is 100%. It maintains full accuracy even at pulse rates up to 4,000/minute, even with pulses that are as brief as 1 millisecond, and even in the face of severe contact bounce, which it ignores by virtue of an extremely effective anti-bounce circuit.

Easy to Set
The ATC Shawnee counter is easily and accurately set even with work gloves on. Push any of its four toggle levers in any sequence until the number you want appears above it. You can decrease as well as increase each number by pushing the levers up or down. You can change the setting at any time, even during a cycle.

Plug-In and Dust Tight
All ATC 356 counters feature true plug-in design and can be replaced in seconds without disturbing the housing or disconnecting the wiring. The dial assembly is gasketed so that the counter body is dust-tight from the front of panel.
Cycle Progress Indication
The ATC Shawnee 356 indicating counter provides cycle progress indication on the four-digit display located immediately above the digital setting number wheels. While the non-indicating Model 356 does not provide true cycle progress indication, it can be wired so that the legend light is on during the cycle and the pilot light flashes with each pulse.
Computer tested Reliability
The solid-state ATC 356 is manufactured from a series of computer-tested plug-in circuit boards and assembled virtually without hand wiring. Because it has no moving parts in its logic circuits, its life expectancy is practically unlimited. Even the load relay – the 356’s only significant mechanical component – has a life expectancy of 10,000,000 operations (no load). As a result the 356 achieves an overall reliability that surpasses even that achieved by previous Shawnee counters.

Noise Immunity
The ATC 356 does not have to be shielded: its transformer power supply, full-wave bridges, buffered logic and other design characteristics render it immune to the electrical noise that is sometimes encountered in industrial environments thus eliminating false starts and reset due to voltage spikes.

OPERATION

The ATC Shawnee 356 operates on a digital logic circuit with three main elements: a pulse circuit; a read-only-memory (ROM) whose output is set by the counter’s digital setting number wheels; and a comparator that continuously examines the outputs of the pulse circuit and ROM.
When power is applied (start signal on), two things happen simulta- neously; the instantaneous DPDT relay is energized transferring both sets of contacts, and the pulse circuit begins to count each input pulse whose duration is at least 1 millisecond. The pulse circuit accu- mulates the count and feeds the total continuously to the comparator. When pulse circuit output exactly equals the output of the ROM, the comparator causes the ATC 356C to count out.
At this point, (1) the DPDT delay relay is energized, immediately transferring both sets of contacts and (2) the pulse circuit turns itself off automatically. Since the pulse circuit stops counting even if the start signal remains on, it is not necessary to tie up one of the ATC 356’s delayed contacts to do this job.
To reset the ATC 356, power must be removed from terminal 1 (L1) for 75 milliseconds or more. The ATC 356 operates in the on-delay mode only, always resetting whenever there is a power outage and starting a new cycle when power is restored. 

Specifications:

Range:
1 to 9999 Counts or 10 to 99,990 Counts
Count Input:
2300/MIN with 1:1 on-off time
4000/MIN with 1 mSEC on: 13mSEC off
500/MIN with 20 mSEC n and 100 mSEC off
Wired for count and repeat operation
Minimum Pulse ON time is 1 mSEC
Minimum OFF time is 13 mSEC
Ready-To-Count time is 10 mSEC after application of power
Bounce Immunity is 6 mSEC (Maximum bounce open time
Pulse Contact Requirement is 30mA (at line voltage)
Cycle Progress Indicator:
4 Digit, 0.3 inch, high intensity blue display
Repeat Accuracy:
100%
Reset Time:
75 mSEC minimum
Minimum Setting:
1 Count
Count Control Modes:
Single Cycle - Interval or delayed
Repeat Cycle - Pulses
Load Relays:
One instantaneous and One delayed, both plug-in and DPDT
Operate Time is 20 mSEC maximum
Release time is Instantaneous - 20mSEC and Delayed - 75mSEC MAX
Contact ratings are 5A at 120VAC and 2A at 240 VAC and .1A at 125 VDC
Contact Life is 100 Million operations (no Load)
Temperature Rating:
32º to 140ºF (0-60ºC)
Input Power Req.:
120V = 95-132V at 50/60Hz, inrush .4A
240V = 190-264V at 50/60Hz, inrush .2A
Terminals:
16 Screw Terminals at rear, wiring diagram on the housing
Housing:
Plug-In Design, completely gasketed and dust tight when panel mounted
Weight:
1 Pound 7 Ounces

Other Counters by ATC:

354C350Q30PX - 120vac - relay output
354C350R30PX - 240vac - relay output
354C353Q30PX - 120vac - relay output
354C353R30PX - 240vac - relay output
354C350Q30PJ  - 120vac with Solid State Output
354C350R30PJ  - 240vac with Solid State Output
354C353Q30PJ  - 120vac with Solid State Output
354C353R30PJ  - 240vac with Solid State Output
(The 353 versions are 10-99,990 counts)

366C400Q30PX - 120vac (count up or count down)
366C400R30PX - 240vac (count up or count down)
366C400T30PX - 24vac (count up or count down)
366C400N30PX - 24vdc (count up or count down)
366C400Q50PX - 120vac (count up and GO or count down and GO)
366C400R50PX - 240vac (count up and GO or count down and GO)
366C400T50PX - 24vac (count up and GO or count down and GO)
366C400N50PX - 24vdc (count up and GO or count down and GO)


Click below to purchase:
ATC series 356C350Q30PX, 9999 counts, digital display, 72x72mm, 120V

ATC series 356C350R30PX, 9999 counts, digital display, 72x72mm, 240V


Sords Electric
216-765-4230
www.sordselectric.com

Sunday, October 28, 2018

ATC Counters from Sords Electric

Automatic Timing and Controls 354 Counters from Sords Electric

Buy Here.
354B350Q30PX 120 volt 9999 Count Counter
354B350Q30PX 240 volt 9999 Count Counter

354C Series Shawnee II High Speed Counter

ATC High Speed 354 Counter












Features:
  • 4 Digit Display
  • Easy to Set
  • Noise Immunity
  • Plug-In & Dust-Tight
  • Control Versatility
  • High Repeat Accuracy
The solid-state ATC 354 is manufactured from a series of computer-tested plug-in circuit boards and assembled virtually without hand wiring. Because it has no moving parts in its logic circuits, its life expectancy is practically unlimited. Even the load relay—the 354’s only significant mechanical component—has a life expectancy of 100,000,000 operations (no load), while the optional solid-state switch module has a virtually unlimited life expectancy. As a result, the 354 achieves an overall reliability that surpasses even the high level achieved by previous Shawnee counters.
CYCLE PROGRESS INDICATION: The ATC Shawnee 354 indicating counter provides cycle progress indication on a four-digit display located immediately above the digital setting number wheels. While the non-indicating Model 354C does not provide true cycle progress indication, its pilot light signals when the counter is running.
EASY TO SET AT ALL TIMES: The ATC Shawnee counter is easily and accurately set even with work gloves on. Push any of its four toggle levers in any sequence until the number you want appears above it. You can decrease as well as increase each number by pushing the levers up or down. You can change the setting at any time, even during a cycle.
NOISE IMMUNITY: The 354 does not have to be shielded: its transformer power supply, full-wave bridges, buffered logic and other design characteristics render it immune to the electrical noise that is sometimes encountered in industrial environments thus eliminating false starts and reset due to voltage spikes.
PLUG-IN AND DUST-TIGHT: All ATC 354 counters feature true plug-in design and are dust-tight from the front of panel. 100% ACCURATE AND BOUNCE-PROOF: The repeat accuracy of the ATC Shawnee 354 is 100% at all rated speeds, even in the presence of contact bounce. The ATC 354 has two selectable levels of bounce suppression: a normal level which eliminates false counts at speeds up to 500 per second with reed switch inputs, and 5,000 per second with DC voltage pulses; and a high level, for speeds up to 80 per second with high-bounce contact closures (relays, precision switches, etc.).
HOUSING, IT OCCUPIES 40% LESS: Packaged in a 72mm2 DIN-size housing, the 354 occupies 40% less panel space than previous IC counters. Modern production and assembly techniques have substantially reduced manufacturing costs resulting in a 45% cost saving.
CONTROL VERSATILITY: The ATC 354 operates either as a repeat cycle pulse generator or in single-cycle interval or delayed mode. You choose the kind of control action you want by installing jumpers on the terminal block. It also provides a choice of control output, a standard plug-in SPDT relay or an optional SPST solid-state switch module…plus an independent and separate DC output signal at Terminal 6.


OPERATION
The ATC Shawnee 354 operates on a digital logic circuit with three main elements: input circuits which allow it to count various types of DC pulses; a read-only-memory (ROM) whose output is set by the counter’s digital setting number wheels; and a comparator that continuously examines the outputs of the input circuit and ROM. When the start (ready/reset) signal is on, the input circuit begins to count incoming pulses, feeding the total count continuously to the comparator. When input circuit output exactly equals ROM output, the ATC 354 counts out. At that instant, the input circuit automatically turns itself off even if the start signal remains on; it is therefore not necessary to turn off the pulses externally. At the same instant, the 354 provides one of three load control actions depending on how it is wired (see Typical Applications). When the 354 is wired for interval operation, the counter’s output device (either the standard SPDT relay or the optional SPST switch module) is energized from the start to the end of the count cycle; so is the DC output at terminal 6. 


Specs:

Range is 1-9999 or 10-99,990 (in tens) Counts

Pulse Inputs 
Minimum Open Resistance: 1 megohm
Maximum Closed Resistance: 20K Ohms
Switch Requirements:  10mA, 30v
Max Count Rate:  500/SEC
Min Closed Time:  100 μSE
Min Open Time:  1 mSEC
Max Open Time: .3 mSEC
Voltage Inputs:
Positive Polarity:  On at 4.5V minimum, Off at 1.0V Maximum
Negative Polarity:  On at 3.0V minimum, Off at 1.0V Maximum
Maximum Continuous Input:    40V
Ripple Voltage: Must not go below requirement
Input Impedance:  5K ohms
Minimum ON time:  60 μSEC
Minimum OFF time: 100 μSEC
Count rate: 5K Hz Maximum
Delayed Mode 
Relay Operate Time:  20 mSEC maximum
Relay Release Time:  25 mSEC maximum
Automatic Recycle Mode
Pulse On Time (with Relay) 80 mSEC, + 20 mSEC
Start (Ready/Reset) Signal
Positive Polarity: ready at 4.5V Minimum, Reset at 1.0V Maximum
Maximum Continuous Input: 40V
Ripple Voltage:  must not go below MIN requirement
Input Impedance: 5K ohms
Ready to Count Time: .5 mSEC
Circuit Reset:  1 mSEC maximum
Ready to Drop Out:  20 mSEC maximum
Start Switch Requirements (Isolated contact)
Switch Rating: 10mA, 30v
Minimum Open Resistance:  1 megohm
Maximum Closed Resistance:  20K ohms
Latching Mode Operation (interval only)
Minimum Duration Start Signal:  50 μSEC
Maximum Start Signal:   continuous
Load Relay
LIFE: 100,000,000 operations with no load
Contact Rating: 5A at 120 VAC, 3A at 28vdc 1/20 HP at 120 VAC
Solid-State Switch Module (optional)
Switches external C voltage supply of positive Polarity, 4 to 30V, 50 mA max
DC Output (Terminal 6)
Voltage: ON 24V +/- 10%
Current: 40mA Maximum
Power Requirements
120V: 95 to 132V, 50/60 Hz, inrush .4A, Running-.02A
240V: 190 to 264V, 50/60 Hz, inrush .4A, Running-.02A
Temperature Rating
32º to 140ºF / 0 60º C
Mounting
Standard - Hardware provided to mount counter to be dust tight on front end of panel
Optional - Surface mounting with front facing terminals

Download Catalog Spec Sheet HERE!

Note - The ATC 354 has gone through 3 updates. The oldest timer was the 354A subsequently followed by the 354B and now the 354C.

Other ATC 354C counters are below

354C353Q30PX - 120vac - relay output
354C353R30PX - 240vac - relay output
354C350Q30PJ  - 120vac with Solid State Output
354C350R30PJ  - 240vac with Solid State Output
354C353Q30PJ  - 120vac with Solid State Output
354C353R30PJ  - 240vac with Solid State Output
(The 353 versions are 10-99,990 counts)