SORDS ELECTRIC sells the Watlow DIN-A-MITE Power Controllers
The Watlow® DIN-A-MITE® Style A power controller provides
a low-cost, highly compact and versatile solid state option
for controlling electric heat. You also get all the quality you
expect from a Watlow designed and manufactured product.
DIN-rail and back panel mounting is standard on every
controller. There is no need to worry about mercury, the
DIN-A-MITE controller is mercury free.
Capabilities include single-phase zero cross switching up
to 25 amperes at 600VÅ(ac) (see rating curve). A unique
integrated design removes the guesswork associated with
selecting a proper heat sink and adequate terminations for
the application.
Variable time base, 4-20mA process control or Vı(ac/dc)
input contactor versions are available. All configurations
are model number dependent and factory selectable. This
power controller also includes 200KA short circuit current
rating (SCCR) tested up to 480VÅ(ac) to prevent arch flash
with required fusing.
The DIN-A-MITE power controller is made in the
United States.
Features and Benefits
200KA Short Circuit Current Rating (SCCR)
• Prevents arc flash
DIN-rail or standard panel mount
• Provides versatility, quickness and low-cost
installation
Compact size
• Reduces panel space; less cost
Touch-safe terminals
• Increases safety for installer/user
No mercury
• Assures environmental safety
Faster switching with solid state
• Saves energy and extends heater life
UL® 508 listed, C-UL® and CE with filter
• Meets applications requiring agency approval
Specifications
Operator Interface
• Command signal input
• Input indicator light LED
Amperage
• Single phase, see the output rating curve
• Max. I2t for fusing: 4000A2sec
• Latching current: 200mA
• Holding current: 100mA
• Power dissipation is 1.2 watts per amperes switched
• 200KA SCCR, Type 1 and 2 approved with the recommended
fusing; see user manual.
Line Voltage
• 20 to 660V~(ac) model number dependent; see ordering
information
• Off-state leakage: 1mA at 77°F (25°C) max.
• 50/60Hz independent
Control Mode-Zero Cross
• Input control signal Type C: VÎ(dc) input contactor
• Input control signal Type K: V~(ac) input contactor
• To increase service life on contactor input models, the cycle time
should be less than three seconds
• Input Control Signal Type F: 4 to 20mAÎ(dc) proportional variable
time base control; 3 cycles on, 3 cycles off at 50% power
Input Command Signal
• AC contactor
24VÅ(ac) ±10%, 120VÅ(ac) +10/-25%, 240VÅ(ac) +10/-25% @
25mA max. per controlled leg
• DC Contactor
4.5VÎ to 32VÎ(dc): max. current @ 4.5 VÎ(dc) is 8mA
per leg
• Loop powered linear current
4mAÎ to 20mAÎ(dc): loop-powered, input Type F0 option only
(requires current source with 6.2VÎ(dc) available, no more than
three DIN-A-MITE inputs can be connected in series)
Agency Approvals
• CE with proper filter:
204/108/EC Electromagnetic Compatibility Directive
EN 61326-1: Industrial Immunity Class A Emissions
2006/95/EC Low Voltage Directive
EN 50178 Safety Requirements
Installation category III, pollution degree 2
• UL® 508 listed and C-UL® File E73741
Input Terminals
• Compression: will accept 0.2 to 2 mm2 (24 to 14 AWG) wire
Line and Load Terminals
• Compression: will accept 0.8 to 8.4 mm2 (18 to 8 AWG) wire
Operating Environment
• Up to 176°F (80°C); see the output rating curve chart for your
application
• 0 to 90% RH (relative humidity), non-condensing
• Installation only tested to 3,000 meters
• Units are suitable for “Pollution degree 2”
Mounting
Options include DIN-rail or standard back panel mounting
• The DIN-rail specification is: DIN EN 50022, 35 mm by 7.5 mm
• Mount the cooling fins vertically
Dimensions
• Height: 3.7 in. (95 mm) high x 1.8 in. (45 mm) wide x
3.9 in. (98 mm) deep
• Weight: 0.71 lb (0.32kg)
Ordering Information
To order, complete the code number on the right with the
information below.
DIN-A-MITE Style A = Solid State Power Controller
DA10 - __ __ __ __ - 0 __ __ __
Phase
1 = 1-phase, 1 controlled leg
Cooling and Current Rating
0 = Natural convection current
rating 18A @ 50˚C (see
derating curve for current rating
at other temperatures)
Line and Load Voltage
02 = 24 to 48VÅ(ac)
24 = 100 to 240VÅ(ac)
60 = 277 to 600VÅ(ac)
Input Type
C0 = 4.5 to 32VÎ(dc) contactor
F0 = 4 to 20mAÎ(dc) proportional
K1 = 22 to 26VÅ(ac) contactor
K2 = 100 to 120VÅ(ac) contactor
K3 = 200 to 240VÅ(ac) contactor
Manual Language
0 = English
1 = German
2 = Spanish
3 = French
Custom Parts Designation
00 = Standard parts
Recommended Semiconductor Fuse and Fuse Holder
Watlow Cooper Bussmann® Ferraz Shawmut
Fuse 17-8025 FWC25A10F L330014
Holder 17-5110 B24202 G81219