Showing posts with label 1 hp. Show all posts
Showing posts with label 1 hp. Show all posts

Saturday, May 12, 2012

Toshiba S11 Drive Adapters



Toshiba S11 Adjustable Speed Drives from Sords Electric 






Optional Conduit Adapters and Dynamic Braking assemblies


Conduit adapters are mounted below the power terminal strips and replace the plastic plate provided with the drive.

Conduit adapters provide mechanical strength and a location for a conduit connector.

This allows wall‐mounting of the S11 where NEMA 1 standards must be met.

The height of the S11 will increase with the addition of the conduit adapter.

Example Part Number :  VFS11‐2004PM‐WN







FRAME S11
Adapter   SIZE DRIVE
NEM110Z A 2004, 2007
NEM111Z A 2004, 2007
NEM120Z B 2015, 2022, 4007, 4015, 6015
NEM121Z C 2022, 2037, 4022, 4037, 6022, 6037
NEM130Z C 2022, 2037, 4022, 4037, 6022, 6037
NEM140Z D 2055, 2075, 4055, 4075, 6055, 6075
NEM150Z E 2110, 2150, 4110, 4150, 6110, 6150


Please note that the Toshiba S11 Drive replace the Toshiba S9 Drive.
Single Phase S11 Drives have an S in the part number,  VFS11S-xxxxxx-WN

Dynamic Braking Packages for the S11 Drive.  Please call or email for quotes.


DYNAMIC BRAKING for Toshiba S11 Drives in NEMA 1 Enclosures
HEAVY DUTY Standard Duty
H P  230 VOLTS 230 VOLTS
0.5 S9‐PBR‐2004‐HD S9‐PBR‐2004‐LD
1 S9‐PBR‐2004‐HD S9‐PBR‐2004‐LD
2 S9‐PBR‐2007‐HD S9‐PBR‐2007‐LD
3 S9‐PBR‐2022‐HD S9‐PBR‐2022‐LD
5 S9‐PBR‐2022‐HD S9‐PBR‐2037‐LD
7.5 S9‐PBR‐2022‐HD S9‐PBR‐2055‐LD
10 S9‐PBR‐2022‐HD S9‐PBR‐2055‐LD
15 S9‐PBR‐2022‐HD S9‐PBR‐2110‐LD
20 S9‐PBR‐2022‐HD S9‐PBR‐2110‐LD
460 VOLTS 460 VOLTS
1 S9‐PBR‐4007‐HD S9‐PBR‐4007‐LD
2 S9‐PBR‐4022‐HD S9‐PBR‐4022‐LD
3 S9‐PBR‐4022‐HD S9‐PBR‐4022‐LD
5 S9‐PBR‐4022‐HD S9‐PBR‐4022‐LD
7.5 S9‐PBR‐4055‐HD S9‐PBR‐4055‐LD
10 S9‐PBR‐4055‐HD S9‐PBR‐4055‐LD
15 S9‐PBR‐4110‐HD S9‐PBR‐4110‐LD
20 S9‐PBR‐4110‐HD S9‐PBR‐4110‐LD
600 VOLTS 600 VOLTS
2 S5‐PBR5120‐HD S5‐PBR5120‐LD
3 S5‐PBR5120‐HD S5‐PBR5120‐LD
5 S5‐PBR5160‐HD S5‐PBR5160‐LD
7.5 S5‐PBR5220‐HD S5‐PBR5220‐LD
10 S5‐PBR5270‐HD S5‐PBR5270‐LD
15 S5‐PBR5270‐HD S5‐PBR5270‐LD
20 S5‐PBR5270‐HD S5‐PBR5270‐LD


Sords Electric can quote on most Toshiba Drives, including the New Toshiba P9 drive for Pumps, the AS1 drive, the G9 drive and GX7 drive

www.sordselectric.com
800-929-2845
CONTACT FORM

Wednesday, June 9, 2010

Toshiba S11 Micro Drives

The Toshiba S11 Adjustable Speed Drive is the next generation of micro drives. The S11 provides maximum torque with precise speed control. It features an easy-to-use, quiet and compact design. A removable terminal board, larger terminals, bidirectional speed search and PID control are just a few features that make this drive stand out against other micro drives. No other micro drive delivers such reliable performance and extensive capabilities at such a competitive price.

************ NOTE ~ NOTE ************

THE S11 DRIVE HAS BEEN REPLACED BY THE   S 15 TOSHIBA   MICRO DRIVE AS OF JANUARY 2013.  Some S11's remain but Toshiba is only manufacturing the S15 DRIVE.  The S15 comes in a standard version and a premium version. Visit our web site for both versions.


************ NOTE ~ NOTE ************









Voltage RegulationAdjustable within the range of 50-600V by correcting the supply voltage (not adjustable above the input voltage)
PWM Carrier FrequencyAdjustable between 2.0KHz-16KHz. (default 12 KHz/current derate applies above 4KHz)
Control SystemSine Wave PWM System
V/Hz PatternOpen Loop Vector, Constant Torque, Variable Torque, Auto Torque Boost, Manual Torque Boost, automatic energy saving, dynamic automatic energy saving, PM motor control, Auto Tuning, Base Frequency 25-500Hz, Torque Boost 0-30%; Start Frequency .5-10Hz
Overload Rating150% for 60 seconds, 200% for .5 second
Frequency SettingPotentiometer and Digital Input on Front Panel, Remote Potentiometer (1-10KOhms), 0-10Vdc (input impedance VIA/VIB=30KOhm), 4-20mAdc (input impedance 250 Ohm, 15 preset speeds by contact closure)
Frequency PrecisionAnalog Input ±0.5% of the Maximum Output Frequency, Digital Input ±0.01% of the Maximum Output Frequency
Frequency Command Resolution0.01Hz Operation Panel, 0.1Hz Analog Input
Output Frequency Range0.5-500Hz (default 0.5 -80Hz, maximum frequency 30-500Hz)
Frequency Jump3 Frequencies with Adjustable Range
PID ControlProportional Gain, Integral Gain and Differential Gain Settings and Control Wait Time
Upper and Lower Limit FrequenciesUpper Limit Frequency: 0 to max frequency, Lower Limit Frequency: 0 to upper limit frequency
Input Terminals8 input terminals programmable to 65 functions. Logic selectable between sink and source.
Analog Inputs(1) 4-20mA, (1) 0-10V or 1-10KOhm Potentiometer Connections
Output Contacts1 Open Collector and 1 Relay contact programmable to 58 functions.
Analog Output1mA / 7.5Vdc or switch selectable to 0-20mA (4-20mA), programmable to 19 functions
Power TerminalsInput (L1, L2, L3), Output (T1, T2, T3), DCL (PO, PA), DBR (PA, PB), DC BUS (PA, PC)
Protective FunctionsStall Prevention, Current Limitation, Output Short Circuit, Overvoltage, Overvoltage Limitation, Undervoltage, Ground Fault, Power Supply Phase Failure, Output Phase Failure, Overload Protection, Overcurrent at Startup, Overtorque, Undercurrent, Overheat, Cumulative Operation Time, Life Alarm, Emergency Stop, Braking Resistor Overload, Various Pre-alarms
RetryASD can automatically clear fault upon trip. Programmable to 10 times with wait time up to 10 seconds between retry.
RestartASD will smoothly catch a freewheeling motor.
AmbientTemperature: -10-50°C, 14-122°F. Humidity 93% non-condensing
InstallationNEMA 1/IP20 (enclosed type)
LED IndicationsRun, Monitor Mode, Program Mode, % and Hz Indication, Frequency Setting Mode by Potentiometer or Up/Down Keys, DC Bus Capacitors Charged
MonitoringOperation Frequency, Operation Frequency Command, Forward/Reverse Run, Output Current, Voltage in DC Section, Output Voltage, Torque, Torque Current, Drive Load , DBR Load, Input Power, Output Power, Monitor of Input and Output Terminals, CPU and Memory Versions, PID Feedback and Frequency Command, Rated Current, Past Trips 1-4, Parts Replacement Alarm, Cumulative Run Time
Selectable Display UnitsCurrent and voltage display selectable between Amps/Volts or % along with scaling factor multiplier.


S9 to S 11 cross reference


TOSHIBA S9 H.P. Volts / Phase TOSHIBA S11
VF S9-2004PL-WN 1/2 230 / 1 and 3 phase - VF S11-2004PL-WN
VF S9-2007PL-WN 1 230 / 1 and 3 phase - VF S11-2007PL-WN
VF S9-2015PL-WN 2 230 / 1 and 3 phase - VF S11-2015PL-WN
VF S9-2022PL-WN 3 230 / 1 and 3 phase - VF S11-2022PL-WN
VF S9-2004PM-WN 1/2 230 / 3 and 3 phase - VF S11-2004PM-WN
VF S9-2007PM-WN 1 230 / 3 and 3 phase - VF S11-2007PM-WN
VF S9-2015PM-WN 2 230 / 3 and 3 phase - VF S11-2015PM-WN      In Stock as of 2/22/2014
VF S9-2022PM-WN 3 230 / 3 and 3 phase - VF S11-2022PM-WN
VF S9-2037PM-WN 5 230 / 3 and 3 phase - VF S11-2037PM-WN
VF S9-2055PL-WN 7 1/2 230 / 3 and 3 phase - VF S11-2055PM-WN
VF S9-2075PM-WN 10 230 / 3 and 3 phase - VF S11-2075PM-WN    In Stock as of 2/22/2014
VF S9-2110PM-WN 15 230 / 3 and 3 phase - VF S11-2110PM-WN    In Stock as of 2/22/2014
VF S9-2150PM-WN 20 230 / 3 and 3 phase - VF S11-2150PM-WN
VF S9-4007PL-WN 1 460 / 3 and 3 phase -  VF S11-4007PL-WN        In Stock as of 2/22/2014
VF S9-4015PL-WN 2 460 / 3 and 3 phase - VF S11-4015PL-WN
VF S9-4022PL-WN 3 460 / 3 and 3 phase - VF S11-4022PL-WN
VF S9-4037PL-WN 5 460 / 3 and 3 phase - VF S11-4037PL-WN
VF S9-4055PL-WN 7 1/2 460 / 3 and 3 phase - VF S11-4055PL-WN   In Stock as of 2/22/2014
VF S9-4075PL-WN 10 460 / 3 and 3 phase - VF S11-4075PL-WN
VF S9-4110PL-WN 15 460 / 3 and 3 phase - VF S11-4110PL-WN
VF S9-4150PL-WN 20 460 / 3 and 3 phase - VF S11-4150PL-WN

In Stock as of February 2014: 
TOSHIBA S9-2022PM-WN
TOSHIBA S9-4055PL-WN

Also review the new Toshiba P9 Drive / Inverter designed for Pump use.

See the product on our Sords Electric web site.

800-929-2845 and ask for Syd our Drives expert.