Littelfuse SE-703 Earth-Fault Relay for Protection

  Littelfuse SE-703 Earth Fault Protection for plants and machines

For a Quote, click HERE!

The SE-703 is a microprocessor-based ground-fault relay for resistance and solidly-earthed systems. It offers sensitive ground-fault detection as low as 25 mA and can be used on systems with significant harmonic content. The SE-703 provides feeder-level protection or individual-load protection. The output contacts can be connected for use in protective tripping circuits or in alarm indication circuits. The analog output can be used with a PLC or a meter. The SE-703 is specifically designed to be Australian AS/NZS 2081 compliant.

Operates on AC solidly grounded and AC resistance grounded systems.

Littelfuse SE-703 Fault Meter








The Littelfuse SE-703 requires an EF Current Transformer

The SE-703 Specifications are:

Input voltages: 24, 120, 240 AC and 12, 24, 48 DC

Dimensions: 3x2.2x4.5 inches

Trip Level: 25-500mA

Trip Time: INST - 500 ms

Contact Operating Mode: Fail-Safe

Contacts: Isolated Form A and Form B

Analog Output: 0-5 V

Reset and Test Buttons provided

Approvals: CE, UL, CSA, C-Tick

Littelfuse SE-703 Part Numbers are:

SE-703-OU   120/240 VAC or VDC control power

SE-703-OD   12/24 DC control power

SE-703-OT   48 DC control power

SE-703-OU   24 VAC control power

Accessories:

EFCT Series Current Transformer Required

PGA-0500 Analog % current meter

PMA-55 or PMA-60 Panel mounting adapters

SE-EFVC voltage clamp





For a Quote, click HERE!

Sords Electric

Cleveland, Ohio

216-765-4230

www.sordselectric.com

Littelfuse SE-703...Littelfuse SE-703...Littelfuse SE-703...Littelfuse

Littelfuse SE-701 Ground Fault Monitor

 Littelfuse SE-701 Ground Fault Protection for plants and machines

For a Quote, click HERE!

The Little Fuse SE-701 is a microprocessor-based ground-fault relay for resistance and solidly-grounded systems. In addition to common systems, it is uniquely suited for use on systems with significant harmonic content. The SE-701 can provide main-plant protection, feeder-level protection, or individual-load protection. Proper current transformer selection provides the desired pickup range. The output contacts can be connected for use in protective tripping circuits or in alarm indication circuits. The analog output can be used with a PLC or a meter.

Littelfuse SE-701 Ground Fault Protection Meter









The Littelfuse SE-701 requires a Current Transformer

The SE-701Specifications are:

Input voltages: 24, 120, 240 AC and 12, 24, 48 DC

Dimensions: 3x2.2x4.5 inches

Trip Level: 1-99% of Primary rating

Trip Time settings: .05 - 2.5 seconds

Contact Operating Mode: Either Fail-Safe or Non Fail-Safe

Contacts: Isolated Form A and Form B

Analog Output: 0-5 V


Reset and Test Buttons provided

Approvals: CE, UL, CSA, C-Tick

Littelfuse SE-701 Part Numbers are:

SE-701-OU   120/240 VAC or VDC control power

SE-701-OD   12/24 DC control power

SE-701-OT   48 DC control power

SE-701-OU   24 VAC control power

Accessories:

Current Transformer (application specific)

PGA-0500 Analog % current meter

PMA-55 or PMA-60 Panel mounting adapters

SE-EFVC voltage clamp





For a Quote, click HERE!